- conform 5-channel relay coupler normaly open contacts Type RKS2-5.24 see table below -25% to 50% UNominal min. 20ms 100% -30°C to +70°C see drawing below -40°C...+105°C self cooling recommended respective distance 10mm each - - - 380.000 h approx. 7mA VDE 0100, 0110, 0113, 0551, 0160/W2, 0806 IEC 60939-1, IEC60939-2,IEC60068-2-3 EN45501, EN50021, EN61000-6-1-2-3-4 CSA-C 22.2 / UL1283, UL94V1 EN55011, EN50204, EN61558-2-17, EN50178 EN60204, EN60529, EN61000-4-2-3-4-5-6-8-11 EN60068-2-1-2-3-6-27-30 IEC 60068-2-11-52,IEC 60529,IEC 380 > 18V approx. 27mA approx. 0,31kg Number of channels Type Switching voltage output Dimensions (W x H x D) Wheight Order-No. Switching current output Switching frequency Nominal input voltage operate time 7ms typ. Impuls width Relapsecurrent of the relay at 20°C Consumption each channel Nominal input voltage Range of input voltage Input data Switching barrier Input current each channel Switching time at nominal voltage Applied construction regulations according to VDE IEC EN CSA / UL Mounting Mechanics Class 2 (EN 60950) 95% relative humidity, yearly average dewing allowed for use in tropical ambient IP 65 IP 20 (VGB4) >30g at 33Hz in X,Y and Z, acc. to IEC 60068-2-27 - Protection class Ambient humidity Protective class enclosure Protective class terminals Vibration proof Extra low safety potential Safety data Safety devices Operating data Duty circle Operating temperature range Derating Storage temperature range Cooling Fuse for input Fuse for output Overload protection MTBF Technical Data On rails acc. to DIN 46277 or wallmounting with screws Input suitable for AC and DC voltage with a combined ground connection Safety acc. to VDE, EN, UL, CSA Operating status shown by LED For high switching power contacts made of precious metal Easy installation on DIN-rails Conform with EMC and guidelines for low voltage Output separated Derating A = in rows with zero spacing B = in rows with 10mm spacing Load current Ambient temperature 0 A B 0 12 10 8 6 4 2 10 20 30 40 50 60 70 80 90 100 Amp. °C see table below see table below max. 3000VA, max. 120W 10W electrical - 7 x 104 mechanical - 3 x 107 Output data Switching voltage Switching current Switching power Minimum switching power Life expectancy (operations) release time 3ms typ. RKS2-5.24 24VAC(VDC) max. 10Hz max. 250VAC max. 48VDC max. 12A AC max. 2,4A DC 55x75x110 59139 5 P.O. Box 1521 22905 Ahrensburg Germany Phone : +494102 - 42082 Telefax: +494102 - 40930 E-Mail : info@feas.de Internet: www.feas.de High voltage resistance Input / Output 3,75 kVAC acc. to VDE 0806 75,0 55,0 110,0

pageCatalog pdf di En 2012-05-22-29