You may also be interested in
Rectifier module, EMC filter, Power filter, Motor controller, DIN rail power supply
Text version of the page
- conform
5-channel relay coupler
normaly open contacts
Type RKS2-5.24
see table below
-25% to 50% UNominal
min. 20ms
100%
-30°C to +70°C
see drawing below
-40°C...+105°C
self cooling
recommended respective distance 10mm each
-
-
-
380.000 h
approx. 7mA
VDE 0100, 0110, 0113, 0551, 0160/W2, 0806
IEC 60939-1, IEC60939-2,IEC60068-2-3
EN45501, EN50021, EN61000-6-1-2-3-4
CSA-C 22.2 / UL1283, UL94V1
EN55011, EN50204, EN61558-2-17, EN50178
EN60204, EN60529, EN61000-4-2-3-4-5-6-8-11
EN60068-2-1-2-3-6-27-30
IEC 60068-2-11-52,IEC 60529,IEC 380
> 18V
approx. 27mA
approx. 0,31kg
Number of channels
Type
Switching voltage output
Dimensions (W x H x D)
Wheight
Order-No.
Switching current output
Switching frequency
Nominal input voltage
operate time 7ms typ.
Impuls width
Relapsecurrent of the relay at 20°C
Consumption each channel
Nominal input voltage
Range of input voltage
Input data
Switching barrier
Input current each channel
Switching time at nominal voltage
Applied construction regulations
according to VDE
IEC
EN
CSA / UL
Mounting
Mechanics
Class 2 (EN 60950)
95% relative humidity, yearly average dewing
allowed for use in tropical ambient
IP 65
IP 20 (VGB4)
>30g at 33Hz in X,Y and Z,
acc. to IEC 60068-2-27
-
Protection class
Ambient humidity
Protective class enclosure
Protective class terminals
Vibration proof
Extra low safety potential
Safety data
Safety devices
Operating data
Duty circle
Operating temperature range
Derating
Storage temperature range
Cooling
Fuse for input
Fuse for output
Overload protection
MTBF
Technical Data
On rails acc. to DIN 46277 or
wallmounting with screws
Input suitable for AC and DC voltage
with a combined ground connection
Safety acc. to VDE, EN, UL, CSA
Operating status shown by LED
For high switching power
contacts made of precious metal
Easy installation on DIN-rails
Conform with EMC and guidelines for low voltage
Output separated
Derating
A = in rows with zero spacing
B = in rows with 10mm spacing
Load current
Ambient temperature
0
A B
0
12
10
8
6
4
2
10 20 30 40 50 60 70 80 90 100
Amp.
°C
see table below
see table below
max. 3000VA, max. 120W
10W
electrical - 7 x 104
mechanical - 3 x 107
Output data
Switching voltage
Switching current
Switching power
Minimum switching power
Life expectancy (operations)
release time 3ms typ.
RKS2-5.24
24VAC(VDC)
max. 10Hz
max. 250VAC
max. 48VDC
max. 12A AC
max. 2,4A DC
55x75x110
59139
5
P.O. Box 1521
22905 Ahrensburg Germany
Phone : +494102 - 42082
Telefax: +494102 - 40930
E-Mail : info@feas.de
Internet: www.feas.de
High voltage resistance Input / Output 3,75 kVAC acc. to VDE 0806
75,0
55,0
110,0
|
|