Control stations
14Pages

{{requestButtons}}

Catalog excerpts

Control stations - 1

EFG Multiple control stations Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) II 2 G Ex d IIB T6/T5 Gb II 2 D Ex tb IIIC T85°C/ T100°C Db EXECUTION RULES OF COMPLIANCE EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES IECEx: IECEx INE 11.0034X INMETRO: CEPEL 13.2253X EAC: TC RU C-IT.ГБ08.В.01323 RUSSIAN MARINE CERTIFICATE (RMRS): 13.03520.315 Mechanical characteristics Body marine grade copper free aluminium light alloy marine grade copper free aluminium light alloy stainless steel Internal plate galvanized steel On Request Accessories: • External epoxy painting with colour on request • Cable entries with different threads from standards Bartec Feam Catalogue

Open the catalog to page 1
Control stations - 2

Explosion Proof Electrical Equipment Reference details EFG - Max. operators allowed diagrams EFG6 EFG6 3 1-2 LEGEND: 1 EFP PUSH BUTTON 2 MORE OPERATORS DETAILS ARE AVAILABLE ON “HANDLES-D” BULLETIN REMARK - (A) TWIN HOLES 1-2 TYPE, CAN BE REPLACED BY ONE HOLE 3 TYPE REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only.

Open the catalog to page 2
Control stations - 3

EFSC218 Thermal magnetic and earth leakage circuit breakers, selector and fused switches Explosion Proof Electrical Equipment Ex Control station Pressacavi Ex Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) II 2 G Ex d IIB T6/T5 Gb II 2 D Ex tb IIIC T85°C/ T100°C Db EXECUTION RULES OF COMPLIANCE EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31; PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES...

Open the catalog to page 3
Control stations - 4

Explosion Proof Electrical Equipment TEMPERATURE CLASS (DUSTS) PADLOCK HANDLE NORMAL HANDLE THREE POLES FUSE SWITCH 500V 50-60Hz THREE POLE SWITCH CIRCUIT BREACKERS CURVE “C” 415V 50-60Hz 6kA FIGURA C RATE DETAIL [In] CODE THREE POLES CODE FOUR POLES EARTH LEAKAGE CIRCUIT BREAKERS 400/230V 50-60Hz 300mA 1PH+N - 3PH+N CODE FOUR POLES FIGURA D FIGURA E FIGURA C THERMAL MAGNETIC MOTOR PROTECTION THREE POLES 660V 50-60Hz REMARK: Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be...

Open the catalog to page 4
Control stations - 5

EFDC Push buttons and control stations Explosion Proof Electrical Equipment Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) II 2 G Ex d IIC T6/T5 Gb II 2 D Ex tb IIIC T85°C/T100°C Db EXECUTION RULES OF COMPLIANCE EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES IECEx: IECEx INE 11.0033X INMETRO: CEPEL 13.2255X EAC: TC RU C-IT.ГБ08.В.01323 RUSSIAN...

Open the catalog to page 5
Control stations - 6

EFDC Technical Features Explosion Proof Electrical Equipment TEMPERATURE CLASS (DUSTS) OPERATORS TYPE OPERATORS LAYOUT (QUANTITY) CODE EXAMPLES: EFDC Standard operators layout ED * WITH BREAKING GLASS (EMERGENCY STOP) ** WITH RED MUSHROOM EMERGENCY PUSH BUTTON FIG. F REMARK:FIG. E FIG. E FIG. F FIG. F Due to the development of the national and international specifications and of the technology, the above technical characteristics showed on this bulletin can be considered as binding on our confirmation only. IONE

Open the catalog to page 6
Control stations - 7

EFSC Rotary switches and selector switches Explosion Proof Electrical Equipment Ex Control station Pressacavi Ex Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) II 2 G Ex d IIC T6/T5 Gb II 2 D Ex tb IIIC T85°C/T100°C Db EXECUTION RULES OF COMPLIANCE EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES IECEx: IECEx INE 11.0033X INMETRO: CEPEL 13.2255X...

Open the catalog to page 7
Control stations - 8

EFSC Technical Features Explosion Proof Electrical Equipment TEMPERATURE CLASS (DUSTS) CODE ON/OFF SWITCHES 500V 50/60Hz 2 POLES 3 POLES CODE CHANGE OVER SWITCHES 500V 50/60Hz 2 POLES 3 POLES 4 POLES CODE TWO WAY SWITCHES 500V 50/60Hz 2 POLES 3 POLES EFSC Motor switch diagram arrangements TYPE “R” TIPO "R""R" "R" control with TIPO Contactor "R" TIPOTIPO TIPO "R" mantained OFF position A-BA-B A-B A-B A-B O 1 1 2 2 21 5 5 6 1 6 65 O OO O1 25 2 TYPE “Y” TIPO "Y""Y" "Y" "Y" TIPO TIPO TIPO "Y" Reverse motor TIPO starter control TIPO "X""X" "X" "X" TIPO TYPE “X” TIPOTIPO TIPO "X" Contactor...

Open the catalog to page 8
Control stations - 9

EFDC3D – EFDC3T Multiple control stations Explosion Proof Electrical Equipment REFERENCE STANDARDS Directive 94/9/EC (until April 19th, 2016) and Directive 2014/34/EU (from April 20th, 2016) II 2 G Ex d IIC T6/T5 Gb II 2 D Ex tb IIIC T85°C/T100°C Db EXECUTION RULES OF COMPLIANCE Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 /22 (Dusts) Classification: Group II - Category 2G 2D EN/IEC 60079-0; EN/IEC 60079-1; EN/IEC 60079-31 PROTECTION DEGREE AMBIENT TEMPERATURE OTHER AVAILABLE CERTIFICATES IECEx: IECEx INE 11.0033X INMETRO: CEPEL 13.2255X EAC: TC RU C-IT.ГБ08.В.01323 RUSSIAN...

Open the catalog to page 9
Control stations - 10

TEMPERATURE CLASS (DUSTS) Reference details Explosion Proof Electrical Equipment *LOW LID, ONLY FOR GLASS WINDOW B 1 MUSHROOM PUSH BUTTON 1 PILOT LIGHT 1 PUSH BUTTON NO 1 PUSH BUTTON NC 1 INSTRUMENT (low lid) 1 CHANGE OVER SWITCH 1 SWITCH OPERATOR ARRANGEMENT: ON EACH COVER IS POSSIBLE TO FIT THE FOLLOWING MATERIAL: • 1 48x48 INSTRUMENT (low lid with glass) • UP TO 3 PILOT LIGHTS (as EFDC…R, see bulletin 65) • UP TO 3 PUSH BUTTON (as EFDC…R, see bulletin 65) • 1 MUSHROOM PUSH BUTTON (as EFDC…, see bulletin 65) • 1 SELECTOR SWITCH (as EFSC…, see bulletin 66) REMARK: Due to the development of...

Open the catalog to page 10

All F.E.A.M. s.r.l. catalogs and technical brochures

  1. Miscellaneous

    12 Pages

  2. Enclosures

    50 Pages