OPERATIONPulse™ 30-180 SeriesControl Instruction Manual STEP 9: DETAILED SYSTEM SETUP CONTINUED There are fourteen ALARM STATUS outputs:• TC OPEN – if selected to an output and TC OPEN occurs, that output will be activated through the closing of the contacts for the N/O standard module.• TC REVERSED – if selected to an output and TC REVERSED occurs, that output will be activated through the closing of the contacts for the N/O standard module.• TC SHORTED – if selected to an output and TC SHORTED occurs, that output will be activated through the closing of the contacts for the N/O standard module.• HEATER OPEN – if selected to an output and HEATER OPEN occurs, that output will be activated through the closing of the contacts for the N/O standard module.• OVER TEMP – if selected to an output and OVER TEMP occurs, that output will be activated through the closing of the contacts for the N/O standard module.• UNDER TEMP – if selected to an output and UNDER TEMP occurs, that output will be activated through the closing of the contacts for the N/O standard module.• OVER TEMP ABORT – if selected to an output and OVER TEMP ABORT occurs, that output will be activated through the closing of the contacts for the N/O standard module.• UNDER TEMP ABORT – if selected to an output and UNDER TEMP ABORT occurs, that output will be activated through the closing of the contacts for the N/O standard module.• OVER % POWER LIMIT – if selected to an output and OVER % POWER LIMIT occurs, that output will be activated through the closing of the contacts for the N/O standard module.• UNDER % POWER LIMIT – if selected to an output and UNDER % POWER LIMIT occurs, that output will be activated through the closing of the contacts for the N/O standard module.• OVER AMPS LIMIT – if selected to an output and OVER AMP LIMIT occurs, that output will be activated through the closing of the contacts for the N/O standard module.• UNDER AMPS LIMIT – if selected to an output and UNDER AMP LIMIT occurs, that output will be activated through the closing of the contacts for the N/O standard module.• AT TEMP – a unique feature that is tied to the SYSTEM modes SOFT SOAK and RUN (reference the “TOOL STARTUP ROUTINE” under “CONTROLLING THE PULSE 2” section in this manual for more details). When AT TEMP is assigned to an output that output will be activated (typically N/O to a closed contact condition) when the SYSTEM MODE changes to RUN.51 |
|