HOW TO...
Pulse™ Series Control Instruction Manual
TROUBLESHOOTING
The following section assists in the most common troubleshooting questions found with the Pulse control system.
Module Troubleshooting
Reference the Module explanation section, page 6 of this manual for more information.
QUICK REFERENCE
GETTING STARTED ................4
Unpacking Your Pulse ................4
What's Included..........................4
Pulse Cabinets............................5
Pulse Modules............................6
Heater & T/C Mold Cables..........8
Connecting AC Power................9
ABOUT..................................10
System Operation....................10
Pulse Screens............................12
Help ........................................14
Main Screen ............................15
Zone Setup Parameters............18
System Setup Screen................31
File System ..............................34
Security....................................35
Alarm......................................38
Printing....................................40
HOW TO................................41
Shutting OFF the Alarm............41
Setting Up Multiple Zones........41
Troubleshooting........................42
System Troubleshooting
Problem: Main screen does not come on.
Possible causes:
Verify AC is applied to the Pulse control system.
Verify all phases are present to the controller.
Verify the Main Circuit breaker is in the ON position.
Verify the CPU module is fully inserted into the Pulse cabinet.
Ensure the display unit connector is fully inserted and locked in place.
Ensure the display unit connector on the CPU module is fully inserted.
Problem: System does not Boost or Idle when I press the Boost or Idle button.
Possible cause: The global timers are not set under the SYSTEM SETUP screen (reference the systems setup screen for more information).
Problem: All zones show open thermocouple.
Possible cause:
Verify the T/C cable is plugged into the correct connector on the Pulse and on the hot runner system. Verify the T/C module is fully inserted and the locking pins are locked.
SPECIFICATIONS
General.................
System .................
WARRANTY ........
.43
Problem: All zones show open heater.
Possible cause: Verify the Heater cable is plugged into the correct connector on the Pulse and on the hot runner system.
Problem: A zone shows an open heater but the heater is actually not open.
Possible cause:
Verify the power module is fully inserted into the Pulse cabinet. Check to see if the fuses are open for that zone.
.44
Problem: A zone shows an open thermocouple but the thermocouple is not actually open.
Possible cause:
Verify the T/C module is fully inserted into the Pulse cabinet. Check the thermocouple fuse for that zone on the T/C module.