Pulse 1 Instruction Manual - Fast Heat - #41

/ 44


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
P. 37
P. 38
P. 39
P. 40
P. 41
P. 42
P. 43
P. 44
Pages:


See other catalogues for Fast Heat

Text version of the page
HOW TO...
Pulse™ Series Control Instruction Manual
SHUTTING "OFF" THE ALARM
SECTION REFERENCE
ABOUT..................................10
System Operation....................10
RUN........................................10
STOP........................................10
BOOST....................................10
IDLE ........................................11
Navigate/Change Values..........11
Pulse Screens............................12
Help ........................................14
Main Screen ............................15
Zone Main Setup......................18
Zone Limits Setup....................21
Zone Boost/Idle Setup..............25
Zone PID Setup........................28
System Setup Screen................31
File System ..............................34
Security....................................35
Security Setup..........................36
Alarm......................................38
Printing....................................40
HOW TO................................41
Shutting OFF the Alarm............41
Setting Up Multiple Zones........41
Troubleshooting........................42
To shut off the alarm light and sounder press the alarm button. This
will immediately silence the alarm and open the ALARM screen indicating the errors encountered. For more information about the ALARM screen reference the ALARM section of this manual. For more information on the errors shown on the ALARM screen reference the alarm error explanation of this manual.
SETTING UP MULTIPLE ZONES
STEP 11 SETTING ZONE NAME
The cursor should be located in the upper left corner of the display highlighting "Zone l's" zone name (see Figure A). Enter the appropriate zone name and reference number for each zone that is going to be RUN using the (-) or (+) buttons. This ensures that "Even Soak" will run properly during system startup. Choose from the following name descriptions and number range:
Zone Name Descriptions:
MNP = Primary Manifold MNS = Secondary Manifold CAV = Cavity or Drop SPR = Sprue
USR = User Defined Zone Name Ref. Number: 00 = From 00 to 99
NOTE: For more info on Main Display contents, reference the "?" (HELP) screen.
Figure A
STEP 2: SETTING ZONE SETPOINT
Move your cursor to the SET (Setpoint) column (see Figure A). Enter the desired setpoint for every zone using the navigation buttons and the (-) or (+) buttons to select a temperature value (System setpoint default is 500°F).
Note: To change the temperature scale to Celsius: press "SYSTEM" button (Function button "F3") from MAIN display; navigate to "Temp Scale"; using the (-) or (+) buttons, change to the "C" setting; press "MAIN" button (Function button "Fl") to return to the MAIN display and continue with setup.
STEP 3: SETTING ZONE MODE
Move the cursor to the MODE column (see Figure A). Enter the desired zone mode using the (-) or (+) buttons. Choose from the following zone mode descriptions:
Mode Descriptions:
OFF = Zone's power is shut OFF to load
MAN = Manual control or Open loop control mode
AUTO = Automatic control or Closed loop control mode
VIEW = Displays actual zone temperature only (ACT column see Figure A)
SLAVE = Allows slaving of selected zone to another zone
41