Pulse™ Series Control Instruction Manual
and the zone does not have another zone that is similar in thermal properties (determined by the Pulse during the Startup Function) and the zone has achieved setpoint the zone's last average power will be applied to the load (forced manual mode).
For more information on Auto Comp reference the Auto Comp section, page 32 of this manual.
SECTION REFERENCE
ABOUT..................................10
System Operation....................10
RUN........................................10
STOP........................................10
BOOST....................................10
IDLE ........................................11
Navigate/Change Values..........11
Pulse Screens............................12
Help ........................................14
Main Screen ............................15
Zone Main Setup......................18
Zone Limits Setup....................21
Zone Boost/Idle Setup..............25
Zone PID Setup........................28
System Setup Screen................31
File System ..............................34
Security....................................35
Security Setup..........................36
Alarm......................................38
Printing....................................40
OPEN HTR (open heater)
Problem: The heater and / or fuse in the zone has been detected as open. Action taken by Pulse:
1. Alarm light and sounder are turned on.
2. Power to the load has been shut off.
TRIAC SHRT (triac shorted)
Problem: A triac short was detected in the zone. Action taken by Pulse:
Alarm light and sounder are turned on. The secondary cut-off relay opened its contacts - turning off power to the zone.
OVER TEMP (over alarm band)
Problem: An over temperature reading has been detected in the zone. Action taken by the Pulse: Alarm light and sounder are turned on indicating the temperature has exceeded the alarm band setting (reference alarm band setting in this manual).
UNDR TEMP (under alarm band)
Problem: An under temperature reading has been detected in the zone. Action taken by the Pulse: Alarm light and sounder are turned on indicating the temperature has exceeded the alarm band setting (reference alarm band setting in this manual).
OVER ABRT (over abort band)
Problem: An over temperature reading has been detected in the zone. Action taken by the Pulse: Alarm light and sounder are turned on indicating the temperature has exceeded the abort band setting (reference abort band setting in this manual).
UNDR ABRT (under abort band)
Problem: An under temperature reading has been detected in the zone. Action taken by the Pulse: Alarm light and sounder are turned on indicating the temperature has exceeded the abort band setting (reference abort band setting in this manual).
39