Pulse™ Series Control Instruction Manual
Range: 1 to 24 zones.
Description: This field cannot be altered as it reflects the hard-wired location of the zones as wired on the supplied cabinet heater/thermocouple connector(s).
QUICK REFERENCE
GETTING STARTED ................4
Unpacking Your Pulse ................4
What's Included..........................4
Pulse Cabinets............................5
Pulse Modules............................6
Heater & T/C Mold Cables..........8
Connecting AC Power................9
ABOUT..................................10
System Operation....................10
Pulse Screens............................12
Help ........................................14
Main Screen ............................15
Zone Setup Parameters............18
System Setup Screen................31
File System ..............................34
Security....................................35
Alarm......................................38
Printing....................................40
HOW TO................................41
Shutting OFF the Alarm............41
Setting Up Multiple Zones........41
Troubleshooting........................42
SPECIFICATIONS ..................43
General....................................43
System ....................................43
Column 2: NAME "Zone Name and Number"
Range of Selection, Column NAME:
CAV (Cavity or drop) indicates the zone is a cavity or drop in the hot runner system.
MNP (Manifold Primary) indicates the zone is a primary manifold in a multi-manifold system, or can be selected for hot runner systems with a single manifold.
MNS (Manifold Secondary) indicates the zone is a secondary manifold in a multi-manifold system.
SPR (Sprue or Nozzle) indicates the zone is the sprue or heated nozzle of the hot runner system.
USR (User defined) indicates this is a non-hot runner application and allows the user to change the PID values after Fast Tune has been applied (reference PID section in this manual for more information on using PID).
Description NAME: Describes the type of zone being controlled. This selection is primarily used for the Evensoak and Auto Slaving functions - please reference the Evensoak or Slaving section in this manual for more details.
Range column NAME #: 1 to 99
Description NAME #: A number assigned to a zone, this is an optional setting allowing for multiple zones of the same type to be assigned a separate number by the user. Example: CAV 01, CAV 02, etc...
Column 3: SET "Zone Setpoint"
Range for temperature setpoints: 0 to 999 deg F or 0 to 999 deg C. Description: In Auto Mode the SET column will indicate the user-specified temperature setpoint for a given zone. In Manual Mode the SET column will indicate the Percent power setpoint applied to the load.
Reference Zone Mode section page 17 for more information.
Note: For ease of use, when this field is highlighted by the cursor, the least significant digit is always highlighted first.
WARRANTY
.44
Column 4: LO-AT "Setpoint Auto Mode (Temperature) LOW End Setpoint"