Pulse™ Series Control Instruction Manual
ZONE SETUP PARAMETERS
The following section describes the four setup screens that allow the user to adjust all zone parameters. They are: Zone Main Setup; Zone Boost and Idle Setup; Zone Limits Setup; and Zone PID setup.
Zone Main Setup
The primary purpose of this screen is to set both the zone's alarm and abort bands, abort type and the T/C read location for a particular zone. This screen is accessed from the Main Screen, or any of the other Zone Setup screens in this section (reference each screen's function button layout for more details).
The Zone Main Setup screen has 7 sections of information displayed in a columnar format as shown below.
QUICK REFERENCE
GETTING STARTED ................4
Unpacking Your Pulse ................4
What's Included..........................4
Pulse Cabinets............................5
Pulse Modules............................6
Heater & T/C Mold Cables..........8
Connecting AC Power................9
ABOUT..................................10
System Operation....................10
Pulse Screens............................12
Help ........................................14
Main Screen ............................15
Zone Setup Parameters............18
System Setup Screen................31
File System ..............................34
Security....................................35
Alarm......................................38
Printing....................................40
HOW TO................................41
Shutting OFF the Alarm............41
Setting Up Multiple Zones........41
Troubleshooting........................42
SPECIFICATIONS ..................43
General....................................43
System ....................................43
FILE: 2 SECURE: 3
oooo
WARRANTY
.44
Fl F2 F3
FUNCTION BUTTONS
F4
ZONE SETUP Function buttons:
The function buttons on this screen navigate to other Zone Setup screens and the Main screen:
F1 MAIN = Go to the MAIN screen.
F2 LIMITS = Go to the setup zone setpoint LIMITS screen.
F3 BST/IDL = Go to the setup BOOST and IDLE setpoints screen.
F4 PID = Go to the PID settings screen.
18