Precision II Technical Specificalo
Operating/Service Instructions
All specifications are subject to change without notification,
Operating & Servicing Instructions
The Precision Series II body designs are identical in diameter, and differ only in length and head style. The Precision Series II features a replaceable sleeve
(2) Head styles
heater. Type "J" thermocouple, and choice of eleven tip styles for a broad range —y of applications.
Start-up/Operating Procedures
If the temperature controller does not utilize "soft start" technology, set the controller to 200°F (93.3°C) in automatic or 10% in manual. Allow nozzle to "soak" for 15 minutes before increasing to processing temperature. This step will allow the unit to dissipate any moisture and prolong heater life.
Tip Removal/Installation
Removal
1) Place nozzle in "V" block and secure it firmly at the nozzle head.
Body
Thermocouple
2) Insert Fast Heat Tip tool Ml 002 (Pinpoint) or Ml 003 (Sprue) provided over/into tip. Use a standard 1/4" Allen socket for Pinpoint tips, or 15mm socket for Sprue tips, and turn counter-clockwise to loosen.
Installation
1) Place nozzle in "V" block and secure it firmly at the nozzle head.
2) Insert Fast Heat Tip tool Ml 002 (Pinpoint) or Ml 003 (Sprue) provided over/into tip.
3) Apply anti-seize sparingly onto male threads of tip.
Note: excess anti-seize may contaminate the resin being processed.
4) Use a standard 1/4" Allen socket for Pinpoint tips or 15mm socket for Sprue tips and install tip by turning clockwise.
5) Torque to 30 ft./lbs. (41 Newton-Meters)
Component Disassembly/Assembly Disassembly
1) Remove "Retaining Ring" using Retaining Ring Pliers.
2) Remove heater by hand.
3) Remove thermocouple by sliding it out of the T/C slot on the body. Assembly
1) Insert pre-bent thermocouple into T/C slot until thermocouple reaches the end of the slot.
2) Slide heater over T/C and body by hand, making sure to place heater wires in the same position as the thermocouple wires.
3) Install "Retaining Ring" using Retaining Ring Pliers.
Power Requirements
« 240 Volts AC - 1 5 amp fuse
■ Grounding - Fast Heat nozzles do not require any additional grounding wire. The nozzles are grounded through the bodies of the components.
• WARNING* |
There must be a ground present between the Mold "Hot Half" and the temperature control system or damage may occur to the nozzle, thermocouple and/or temperature control system
Sleeve Heater
Retaining Ring
! T
(11) Tip Styles
International Manufacturing & Sales Offices: U.K. Tel: (44) 01323 647375 France Tel: (33) 4 77 49 36 46 Singapore Tel: (65) 398 0220
Hot Runner Systems by Fast Heat I-877-RUNRHOT - (877-786-7468)
776 Oaklawn Avenue, Elmhurst, IL 60126 Ph: 1-630-833-5400 ■ Fax: 1-630-833-5414
fasttJheat
www.fastheat.com ■ email: hotrunner@fastheat.com
Z802II3C R400

pageCatalog pdf di En 2012-05-22-29