Shock Absorber and Sensor Accessories
Hydraulic Shock Absorbers^ -
Order separately by part numbers from this chart
Ace Brand Fabco-Air Part #
Enidine Brand Fabco-Air Part #
Thread Size
For use on these models
-
ES06
3/8 - 32
375
AS08
ES08
1/2 - 20
500, 625
AS16
ES16
1.0-12
750
t Note: These are general purpose shocks stocked by Fabco-Air. Other sizes, brands, etc., are available by special order.
Lockplate replaces jam nut and is provided with slide when insert is specified Model EO750-200 shown with Shock Absorbers
Magnetic Piston Position Sensing - For "EG" Style Slides Only
Magnetically operated reed switches and electronic sensors are available in two mounting styles: one is fastened to the cylinder barrel with a band clamp (not included with sensor - must be ordered separately); the other with an adhesive-backed mounting rail with dovetail slots (Option "E"). A magnetic band on cylinder piston is standard.
Clamp On Style Sensors
11 vn
Sensor Type
Prewired 9 ft. Part No.
Quick Disconnect Part No*
LED
il
Electrical Characteristics
Reed Electronic Electronic
9-2A197-1003 9-2A197-1031 9-2A197-1032
9-2A197-1303 9-2A197-1331 9-2A197-1332
Yes Yes Yes
5-120 VAC/VDC, 0.5 AMP Max, 10 Watt Max, SPST N.0.3.5 voltage drop Sourcing, PNP, 6-24 VDC, 0.5 Amp Max, 1.0 voltage drop Sinking, NPN, 6-24 VDC, 0.5 Amp Max, 1.0 voltage drop
Universal Band Clamp - Part Number 800-A00-000 - must be ordered separately
*Note: Quick disconnect style switches are supplied with male connector. Order female cordsets separately.
. -
Dovetail Style Sensors - requires Option -
=: Dovetail Mounting Rail (See description page 9) .
Sensor Type
Prewired 9 ft. Part No.
Quick Disconnect Part No*
LED
s,
Electrical Characteristics
Reed Reed Electronic Electronic
949-000-001 949-000-002 949-000-031 949-000-032
949-000-301 949-000-302 949-000-331 949-000-332
No Yes Yes Yes
0-120 VDC/VAC, 0.5 Amp Max current, 10 Watt Max, 0 Voltage Drop 5-120 VDC/VAC, 0.03 Amp Max current, 4 Watt Max, 2.0 Voltage Drop Sourcing PNP 6-24 VDC, 0.20 Amp Max current, 0.5 Voltage Drop Sinking NPN 6-24 VDC, 0.20 Amp Max current, 0.5 Voltage Drop
*Note: Quick disconnect styles are supplied with 6 inch pigtail with male connector. Order female cordsets separately.
Model EG375 shown above with Clamp On Style Sensors; below with Dovetail Style
Female Cordsets for Quick Disconnect
Length
Part No.
1 Meter
2 Meters 5 Meters
CFC-1M CFC-2M CFC-5M
Stopbolt Actuated Sensors - For "EO", "EG" a
Stopbolt Actuated Sensors...
are comprised of three separate components:
■ WM style stopbolt with actuator pin.
■ Part #AH2 - Actuator Housing which attaches to any of the three sizes of WM style stopbolts.
■ Dovetail style reed switch or electronic switch that mounts in a dovetail slot in the actuator housing.
How they work...
• Actuator housing #AH2 contains a spring loaded magnetic plunger.
■ This housing attaches to the stopbolt with a set screw engaging a groove. Loosening the set screw allows the housing to swivel during stopbolt adjustment.
■ Reed or electronic switches mount in the housing dovetail slot.
■ At the end of stroke, the stopbolt actuator pin pushes the magnet plunger to actuate the sensor.
EU" Style SI
Dovetail Sensor
-.12
Jam Nut "
(Included) 4
.¿.1 : i i ì\
T T
r
.54
.79
.50
- Stopbolt Actuator Pin
1.75
Guide to Ordering Slides with Stopbolt Actuated Sensors
1. Order slide with AM08, AM10, or AM12 threaded inserts.
2. Order required quantity of Code "WM" stopbolts w/actuator pin in a matching thread size.
3. Order required quantity of #AH2 Actuator Housings.
4. Order required quantity of Dovetail Sensors. Select
desired Electrical characteristics and wire type from the table above.
Page 19
1-20-99
Specifications subject to change without notice or Incurring obligations

pageCatalog pdf di En 2012-05-22-29