Product Catalogue 2009 - Evikon MCI - #3

/ 34


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
Pages:


See other catalogues for Evikon MCI
You may also be interested in

RTD, Temperature sensor, Thermocouple, Process controller, Probe


Text version of the page

EvikonEvikon

Sensor Technologies · Measurement & Control InstrumentationSensortehnika · Mõõtevahendid · Kontrollseadmed Catalog 2009

Push-in RTD Probes with Cable 1.21

• For measuring temperatures from -50 to +500 °C• Pt100, Pt500, Pt1000, PTC1000 or NTC resistance sensors • Double RTD sensing element option• AISI 316 stainless steel protection tube • Available in 2-wire, 3-wire or 4-wire circuit• PVC-, silicone-, teflon- or fiberglass-insulated cable

ET20x series push-in resistance temperature probes are intendedfor measuring temperatures in liquids and gases. Applications include heating and cooling installations, building and industrial automation, labs.Depending on the needs of application, platinum RTD sensingelements with specific nominal resistance and accuracy class fortemperatures up to +500 °C and common thermistors, protection tubes of various sizes, connection cables for dry and humid conditions, various process connection fittings and flexible stainlesssteel armour can be supplied.The standard version includes Pt100 class B sensor withmeasurement range from -50 to +250 °C and 3 meters of 3-wire silicone insulated cable.Sensing element - Pt100, Pt500 or Pt1000 RTD sensor, class B, A, 1/3B or 1/10B according to EN 60751, measurement range -50...+250 °C or -50...+500 °C - PTC1000 thermistor (1000 Ohm @ 25 °C), range -30...+150 °C - NTC10A thermistor (10 kOhm @ 25 °C), range -30...+150 °CProtection tube - 1.4404/AISI316L acidproof steel Ø3...15 mm, L30...2000 mm (tubes in stock have Ø4 and Ø6 mm and length L = 30/80/130/190/230/290/380/530 mm), - PTFE coating option for agressive conditionsConnection cable - 2-, 3- or 4-wire circuit, shielded or not; - maximum operating temperature (continuous/peak): silicone-insulated 180/230 °C, teflon-insulated 260/310 °C, fiberglass-insulated 480/530 °C - transition options from cable to protection tube for strain relief: standard (IP55) or waterproof (IP68)

ET20x

L 50
ØD E2060
Ï‘ 4-20 mA0-10 VRS485 Modbus RTU 12(3)(4)

Ï‘

AFxx

A ccessories - flanges and screw fittings, series EA0xx - threaded compression fittings, series EA1xx - threaded thermowells, series EA2xx - flexible stainless steel armour for cable, series SSAxTo provide 4-20 mA / 0-10 V analog output or digital RS485Modbus RTU interface, E2060 series transmitters mountable onto

Fxxx

w all and DIN-rail are available (see: sheet 1.51).

EA8xx

Evikon MCI OÜ Riia 185, 51014 Tartu, Estonia Tel:+372 7336310 Fax:+372 7383041 www.evikon.ee info@evikon.ee