Text version of the page
Text version of the page
EvikonEvikon Sensor Technologies · Measurement & Control InstrumentationSensortehnika · Mõõtevahendid · Kontrollseadmed ? 4-20 mA or 0-10 V analog outputs? In-Head, DIN-rail and wall-mount versions
? Programmable to the required sensor type and analog output scale? Linearization of RTD and thermocouple output characteristics and thermocouple cold-junction compensation? RS485 Modbus RTU interface option for direct Fieldbus networkin g Programmable transmitters E2060 with 4-20 mA current or0-10 V voltage output, mountable into DIN B terminal head, onto
wall or DIN-rail, are intended for signal conditioning of mostcommmon resistance temperature detectors and thermocouples. Microprocessor technology applied in device ensures highmeasurement accuracy, stability and linearisation of sensor
characteristics. Using special software, the transmitter can beprogrammed by the manufacturer or a user to the required sensortype and analog output scale.RS485 digital interface with Modbus RTU protocol enablesadjustment and serial networking of transmitters and industrialcontrollers on RS-485 bus. Input Versions E2060-RTD-... for RTD sensors - Pt100, Pt1000 and other platinum, nickel and brass sensors - 2- or 3-wire circuit, sensor current <0,6 mA
Versions E2060-TC-.. for thermocouples
- Type B, E, J, K, L, N, R, S, T, U thermocouples
- cold-junction compensation range -40...+80 °CAnalog output - 2-wire 4-20 mA (versions E2060-..-I ) - 3-wire 0-10 V (versions E2060-..-U )
output scale freely adjustable in -200...+2000 °C range resolution 0,04 % of output scale
accuracy < (0,2 °C + 0,1% of output scale) @ 22 °C
ambient temperature effect <0,05% of output scale per 10 °C
supply voltage effect <0,01% of output scale per VDigital interface module A2060-485 - provides direct RS-485 Fieldbus networking on sensor level - simple, open and free Modbus RTU communication protocolSupply 9...30 VDC (versions E2060-..-I )
18...30 VDC (versions E2060-..-U )Operating conditions -40...+75 °C, 5...95 %RHElectromagnetic compatibility (CE marking) according to 89-336-EEC and EN61326-1 requirementsEnclosure options -A03: mountable into DIN B terminal head, Ø44×19 mm, IP20 -CMEB: mountable onto DIN-rail, ABS case M1 dimension, IP20 -ET208: mountable onto wall, ABS case 64×96×38 mm, IP54 E2060 E2060-A03 A2060-485 44 33 > +UAB-U Ø44 123456 > 3 × Ø4 20 19 7 > - R - L + Out 4-20 mA + 123456 > Us=9..30 VDC GND - R - L + Out 0-10 V + 123456 > -CMEB Us=15..30 VDC 45 90 > E2060+A2060E2060+A2060 18 123456 > +UA
B-U -ET208 98 123456 > +UAB-U
RS485 RS485RS232 64 38 Evikon MCI OÜ Riia 185, 51014 Tartu, Estonia Tel:+372 7336310 Fax:+372 7383041 www.evikon.ee info@evikon.ee
|