catalogue search
|
You may also be interested in
Limit switch, Relay, Safety switch, Safety relay, Safety device
Text version of the page
General
Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 9
After undoing the four fastening screws, the actuating head can be rotated
in 90° steps. If for reasons of protection against tampering, renewed
removal of the actuating head is to be prevented, the actuating head
can be fastened to the basic housing using safety screws. You will find
appropriate fixings in the accessories section of this catalog.
Changing the switching direction
In addition, the actuating direction can be adjusted such that the actuator
only switches in one direction.
Changing the approach direction safety switch NX/TX
A B
Changing the approach direction
single hole fixing limit switch N1A/NB01
Position
Use
Actuation
Active
Both sides
left + right
State
Pos.driven contacts
NO contacts closed
closed
open closed
One side left
State
One side
right
State
Pos.driven contacts
NO contacts closed
closed closed
open open
Pos.driven contacts
NO contacts
closed closed
open open closed
Use
white
red
white
red
red
white
white
red
Left Not activated Right
red
white
Changing the switching direction position switch NZ.H...
Changing the approach direction safety switch NZ (4 x 90°)
Lever arm Plunger
Changing the approach direction safety switch TZ
. .
.
C
B
D
E (A) Approach direction as
set on delivery
D
C
4
3
1
2
B
E (A)
Solenoid
Actuating head
Changing the approach direction safety switch NZ.VZ.VS (4 x 90°)
Approach direction
as set on
delivery
Position
as set on
delivery
Changing the approach direction safety switch STA
A
D
B
C
|