catalogue search
|
You may also be interested in
Safety switch, Limit switch, Interlock switch, Relay, Safety relay
Text version of the page
For safety precautions see page 196
For technical data see page 163
Safety Switches with Safety Function, Metal Housing
Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 19
Dimension drawings
Wiring diagrams
Ordering table
Cable entry M16 x 1.5
Exterior diaphragm
Plug connector SVM5
M12 plug, 5-pin
21
22
21 22
508
PE
508
21
22
13
14
13 14
21 22
514
PE
514
1
2
3
4
13 14
21 22
SVM5
PE
514
R4
28
39
7 11
35
6,8
76
26±0,1
4 H12
8
18
30° max.
12-0,5
60 (508) / 76 (514)
For cable glands
see page 132
Dog
Cable entry
M16 x 1.5
R4
28 39
76
7 11
35
6,8
76
26±0,1
4 H12
8
18
30° max.
20
12-0,5
For mating connectors
see page 132
Dog
Adjustable male socket
(max. 270°)
Series Actuator Connection
Switching
Version
Function display
element Without LED
508 Exterior 090547
Cable 1 NC diaphragm N1AR508AM-M
R entry
M16 x 1.5 514 Exterior 087158
N1A
Roller
plunger 1 NC + 1 NO diaphragm N1AR514AM-M
8 mm
Plug connector
514 087604
SVM5
1 NC + 1 NO N1AR514SVM5-M
(M12 plug)
1) Approval pending
1) 1)
|