Position Switches
Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 51
Inductive switching elements according
to NAMUR
These switching elements fulfill the
specification IEC 60 947-5-6 and
IEC 61 934.
The current consumption at UB = 8.2 V is
greater than 2.5 mA when the oscillator
face is not activated and less than 1.0
mA when the oscillator face is activated.
The current consumption characteristic is
linear during the transition from the
inactivated to the activated state of the
oscillator face, i.e. these switches do not
have a snap action.
Customized versions
DC-2-wire switching elements
Two-wire switching elements can be used
in principle instead of mechanical switches.
Their low off-state current makes them
especially suitable for use in conjunction
with programmable logic controllers.
Compared with three-wire switching
elements they have the advantage of
requiring less wiring.
The inductive switching elements are
largely protected against external interference
by use of various circuit techniques
(suppressor circuits).
For utilization category DC-13 the output
is to be protected with a free-wheeling
diode for inductive loads.
Short-circuit and overload protection
The inductive switching elements are
designed so that short circuits cannot
damage the outputs. Pulsed short
circuit protection is used.
This means that the output transistor is
switched off and on again in quick
succession in the event of overloading or
a short-circuit. In this way, it is possible to
establish whether the fault is still present
or has been rectified.
Suppressor circuits
Transient protection
EUCHNER proximity switches are protected
against interference caused by the
occurrence of inductive voltage peaks in
accordance with IEC 801-4.
The respective values are specified in the
technical data. Testing is performed in
accordance with the stipulations in
DIN VDE 0660, Part 208 and IEC 947-5-2.
Wire break safety
The EUCHNER proximity switches with wire
break safety are designed such that on a
wire break on any connection, the switch
does not output a spurious signal.
Reverse polarity protection
Protection against reverse polarization of
the operating voltage.
Increased operating distance
For designs with 12 mm proximity switch
spacing, switching elements with increased
operating distance are available on
request (sn = 5 mm).
Due to their technical characteristics,
these switching elements can be used
both with a pulsed operating voltage and
an operating voltage that is not pulsed.
|
|