catalogue search
|
You may also be interested in
Limit switch, Safety device, Safety switch, Interlock switch, Safety relay
Text version of the page
Subject to technical modifi cations; no responsibility is accepted for the accuracy of this information. 9
System Overview
Safety switches with
semiconductor outputs,
pulsed
In series connectable safety switches with
semiconductor outputs,
pulsed
Read head integrated Read head integrated Read head integrated
Without guard locking Without guard locking
Č Stand alone operation
Č Pulsing of safety outputs
Č Short-circuit monitoring
Č Cross circuit monitoring
Č Stand alone operation
Č Switching of high currents
Č Pulsing of safety outputs
Č Short-circuit monitoring
Without guard locking
CES-AP-C01-CH
CES-AP-CL2-AH
CES-AP-CR2-AH
CES-AP-CL2-CH
CES-AP-CR2-CH
CES-AH-C03-AH
Č Stand alone operation
or connection in series
Č Pulsing of the safety outputs
Č Short-circuit monitoring
Č Cross circuit monitoring
More products of the
system family ...-AR
with series connection
and pulsing of the
safety outputs
Modular
safety solution with
guard locking and bolt
Evaluation electronics and read head integrated in the switch
Without
guard locking
With guard locking
and
guard lock monitoring
Further information
see catalog
With guard locking Multifunctional Gate Box
and guard lock monitoring
CES-AR-CR2-AH
CES-AR-CR2-CH
CES-AR-CL2-AH CES-AR-C01-AH CET-AR-CRA-AH CET-AR-CDA-AH
CES-AR-CL2-CH CES-AR-C01-CH CET-AR-CRA-CH
CES-AR-C01-EH
Subject to technical modifications; no responsibility is accepted for the accuracy of this information. © EUCHNER GmbH + Co. KG 110385-01-04/10
Actuators Versions Evaluation electronics and read head integrated System family
CES-AH CES-AP CES-AR
Housing C3 Housing C2 Housing C2 Housing C1 Single
insertion slide
Double
insertion slide
MGB-...-AR
Unicode:
Multicode:
Unicode:
Multicode:
Unicode:
Multicode:
Fixcode:
Housing C1
Cat.3 / PL d Cat. 4 / PL e
Cat. 4 / PL e Cat. 4 / PL e Cat. 4 / PL e Cat. 4 / PL e Cat. 4 / PL e
CES ordering code for switches:
CES-[system family]-[type of coding]-[max. no. of read heads]-[technology (e.g. ASi, ATEX)]
Example: CES-AZ-AES-01B-EX
CES-[system family]-[design of housing]-[type of coding]-[type of connection]-[order no.]
Example: CES-AR-C01-AH-SA-098941
CES ordering code for evaluation units:
(see page 89) (see page 99) (see page 119)
Safety switches with
semiconductor outputs,
pulsed
In series connectable safety switches with
semiconductor outputs,
pulsed
Read head integrated Read head integrated Read head integrated
Without guard locking Without guard locking
Č Stand alone operation
Č Pulsing of safety outputs
Č Short-circuit monitoring
Č Cross circuit monitoring
Č Stand alone operation
Č Switching of high currents
Č Pulsing of safety outputs
Č Short-circuit monitoring
Without guard locking
CES-AP-C01-CH
CES-AP-CL2-AH
CES-AP-CR2-AH
CES-AP-CL2-CH
CES-AP-CR2-CH
CES-AH-C03-AH
Č Stand alone operation
or connection in series
Č Pulsing of the safety outputs
Č Short-circuit monitoring
Č Cross circuit monitoring
More products of the
system family ...-AR
with series connection
and pulsing of the
safety outputs
Modular
safety solution with
guard locking and bolt
Evaluation electronics and read head integrated in the switch
Without
guard locking
With guard locking
and
guard lock monitoring
Further information
see catalog
With guard locking Multifunctional Gate Box
and guard lock monitoring
CES-AR-CR2-AH
CES-AR-CR2-CH
CES-AR-CL2-AH CES-AR-C01-AH CET-AR-CRA-AH CET-AR-CDA-AH
CES-AR-CL2-CH CES-AR-C01-CH CET-AR-CRA-CH
CES-AR-C01-EH
Actuators Versions Evaluation electronics and read head integrated System family
CES-AH CES-AP CES-AR
Housing C3 Housing C2 Housing C2 Housing C1 Single
insertion slide
Double
insertion slide
MGB-...-AR
Unicode:
Multicode:
Unicode:
Multicode:
Unicode:
Multicode:
Fixcode:
Housing C1
Cat.3 / PL d Cat. 4 / PL e
Cat. 4 / PL e Cat. 4 / PL e Cat. 4 / PL e Cat. 4 / PL e Cat. 4 / PL e
CES ordering code for switches:
CES-[system family]-[type of coding]-[max. no. of read heads]-[technology (e.g. ASi, ATEX)]
Example: CES-AZ-AES-01B-EX
CES-[system family]-[design of housing]-[type of coding]-[type of connection]-[order no.]
Example: CES-AR-C01-AH-SA-098941
CES ordering code for evaluation units: