General
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
In typical applications 2, 3 or 4 digits of these 8 (CIS3AMini) or 32 (CIS3/
CIS3A) possible digits are combined to form a number and used in the
application. Hereby, e. g. 150 product carriers (3 digits) with 001, 002,
003 to 150 are sequentially numbered in decimal notation. The definition
of the sequence of numbers with leading zeros produces a logical series.
The data carrier then has a data record address that is used to store the
actual production information in the control system. In this example with
3 available digits, 999 different product carriers could be addressed in
decimal notation. In the case of a 3-digit number, the data are provided
on the 4-bit data wire in the following sequence: the first digit is displayed
automatically, the second digit is displayed after the first SKIP pulse from
the control system and the third digit is displayed after the second SKIP
pulse.
There exist the following possible ways of programming the data carriers
with digits:
Order programmed data carriers
Program in-house using read/write station with serial interface
Program in-house using mobile hand-held terminal
The data carrier can be written (programmed) for read-only operation on
customer request and also visibly labelled using a laser. In this case a data
carrier programming and labelling information form is to be completed with
the order. This form is available for download from www.euchner.de.
You will have significantly more flexibility if you have your own facility for
data carrier programming. The read/write station for the related ident
system with a serial interface can be used on a PC for easy writing to
ƒô
ƒô
ƒô
the data carriers (programming). For this purpose the programming software
Transponder Coding (TC) is installed on the PC. TC is an ASCII/hex
editor with which it is easy to write to and read from the data carrier on
the PC.
It is also possible to write to and read from data carriers with the aid of the
portable mobile hand-held terminal MHT-G2. For this purpose a read/write
head to suit the related ident system is fitted. The data carriers can be
read and written (programmed) using the software Transponder Coding
CE (TCCE). TCCE is an ASCII/hex editor with which it is easy to write to
and read from the data carrier on the MHT.
Integration for read/write operation
In the case of read/write stations with serial interface, the data communication
is according to the 3964R transfer protocol. The individual
commands, e. g. for reading the data or writing the data, are described
in the device-specific manuals. For unusual CIS applications in which data
carriers must also be re-programmed during production, the application
is programmed in the control system with the aid of these commands
based on the 3964R transfer protocol.
Interfacing of a read/write station with serial interface to the user's
PC-based application is supported by the optionally available ActiveX®
modules (can be used if Microsoft Windows®-based user programs support
ActiveX®). CIS can thus be used in conjunction with PC-based control
software or visualization software. The ActiveX® module is used here as
a protocol driver for the 3964R transfer protocol. You can obtain further
information on the usage of an ActiveX® module on request.
Microsoft Windows® and ActiveX® are registered trademarks of Microsoft Corporation
Block diagram ident system CIS3/CIS3A
Block diagram ident system CIS3A-Mini
0815EEEE
Serial interface
Control system
PLC
PC
Parallel interface Input
Input
Input
Input
Input
Output
Output
Read/write station
Read-only station
Static reading/
writing, data
carriers with
116 bytes can
be used
Static reading,
data carriers
with 8 digits
can be used
STROBE
A
B
C
D
SKIP
Value 1
Value 2
Value 4
Value 8
RESET
0815EEEE
max. 5 m for RS232 / max. 1000 m for RS422
screened
max. 15 m max. 15 m
screened
max. 15 m
screened
Read-only head
Read/write head
Static reading/
writing, data
carriers with
32 digits can
be used
Static or dynamic
reading, data
carriers with
32 digits can
be used
Value 1
Value 2
Value 4
Value 8
max. 5 m
screened
max. 50 m
screened
Control system
PLC
PC
Serial interface
Parallel interface
Input
Input
Input
Input
Input
Output
STROBE
A
B
C
D
SKIP
|