video corpo

ETIBREAK Moulded case circuit breakers and switch disconnectors
68Pages

{{requestButtons}}

Catalog excerpts

ETIBREAK Moulded case circuit breakers and switch disconnectors - 1

ETIBREAK Low breaking capacity moulded case circuit breakers EB2S EB2 and low voltage switch disconnectors ED2 ETIBREAK ETIBREAK Low voltage moulded case circuit breakers 312 Low voltage moulded case circuit breakers with residual current protection EB2R Technical data Moulded case circuit breakers and switch disconnectors POWER NEEDS CONTROL

Open the catalog to page 1
ETIBREAK Moulded case circuit breakers and switch disconnectors - 2

etibreak £Tt Low breaking capacity moulded case circuit breakers Low breaking capacity moulded case circuit breakers Advantages of low breaking capacity MCCBs New series EB2S of MCCBs has excellent performances with reduced dimensions and new modern design. Unique accessory cover opens with only one screw. Practical internal accessories can be installed with one touch: - auxiliary switch - alarm switch - shunt trip unit - undervoltage trip unit Customer can select between fixed and adjustable protection: EB2S series complies to safety recommendation standard IEC 60204-1. EB2S is marked with...

Open the catalog to page 2
ETIBREAK Moulded case circuit breakers and switch disconnectors - 3

4 1,00 Technical data on page 363 307

Open the catalog to page 3
ETIBREAK Moulded case circuit breakers and switch disconnectors - 4

Low breaking capacity moulded case circuit breakers 1,0 308 Technical data on page 363

Open the catalog to page 4
ETIBREAK Moulded case circuit breakers and switch disconnectors - 5

etibreak EB2S 250 adjustable protection Technical data on page 363 309

Open the catalog to page 5
ETIBREAK Moulded case circuit breakers and switch disconnectors - 6

Low breaking capacity moulded case circuit breakers Auxiliary switch, PS2S 160-250 Alarm switch, SS2S 160-250 Shunt trip unit, DA2S 160-250 AC 200-240V Shunt trip unit, DA2S 160-250 AC 380-450V Shunt trip unit, DA2S 160-250 DC 24V Undervoltage trip unit, NA2S 160-250 AC 200-240V Undervoltage trip unit, NA2S 160-250 AC 380-450V Undervoltage trip unit, NA2S 160-250 DC 24V External accessories Accessories for EB2S 160 Breaker mounted handle, RO2S 160 Panel mounted handle, RO2S 160P Attach busbar, ZB2S 160/3 Spread Attach busbar, ZB2S 160/4 Spread Interpole barrier, IZ2S 160 Terminal covers,...

Open the catalog to page 6
ETIBREAK Moulded case circuit breakers and switch disconnectors - 7

etibreak Technical data on page 369 311

Open the catalog to page 7
ETIBREAK Moulded case circuit breakers and switch disconnectors - 8

Low voltage moulded case circuit breakers and low voltage switch disconnectors Low voltage moulded case circuit breakers are used for the switching and protection of power supply cables, motors and other electrical equipment against overloads and short circuit faults. They provide, beside protection function, other functions as remote ON/OFF operation, undervoltage protection, main switch etc. They are available in range from 20 A up to1600 A in 3 and 4 pole versions. Advantages: ■ Small dimensions,modular sizes ■ Possibility of field-instalable accessories - up to 1600A frame size series 2...

Open the catalog to page 8
ETIBREAK Moulded case circuit breakers and switch disconnectors - 9

Technical data on page 331 313

Open the catalog to page 9
ETIBREAK Moulded case circuit breakers and switch disconnectors - 10

Low voltage moulded case circuit breakers and low voltage switch disconnectors ETIBREAK EB2 160/250 314 Technical data on page 331 - 334

Open the catalog to page 10
ETIBREAK Moulded case circuit breakers and switch disconnectors - 11

Technical data on page 334 315

Open the catalog to page 11
ETIBREAK Moulded case circuit breakers and switch disconnectors - 12

Low voltage moulded case circuit breakers and low voltage switch disconnectors Microprocessor's MCCBs Microprocessor's MCCBs are available in frame sizes from 250 A up to 1600 A, with rated current from 40 A up to 1600 A. All frame sizes have adjustable thermal and magnetic protection. Series 2: Protection against overload can be adjusted between 0,4 - 1 x In, meanwhile short-circuit protection has already preset different curves, which can be easily selected according to the type of load. Optional Functions: N - Neutral Protection A - Standard relay with LSI Characteristic (where no...

Open the catalog to page 12
ETIBREAK Moulded case circuit breakers and switch disconnectors - 13

Technical data on page 332-334 317

Open the catalog to page 13
ETIBREAK Moulded case circuit breakers and switch disconnectors - 14

Low voltage moulded case circuit breakers and low voltage switch disconnectors Low voltage switch disconnector ETIBREAK ED2 ETIBREAK ED2 125-1600 Note: All internal and external accessories for MCCBs can also be mounted to corresponding type of switch disconnectors. 318 Technical data on page 334, 337

Open the catalog to page 14
ETIBREAK Moulded case circuit breakers and switch disconnectors - 15

Low voltage moulded case circuit breakers with residual current protection Low voltage moulded case circuit breakers with residual current protection Main features and advantages Adjustable residual current tripping thresholds between 30mA and 3A. Adjustable time delay for residual current protection between 60ms and 700ms including INST (instantaneous) and NT (No Trip). Type A: Tripping is ensured for residual sinusoidal AC in the presence of residual pulsating DC. Voltage Presence LED Indicator and Trip Indicator (the yellow button pops up to indicate tripping due to residual current)...

Open the catalog to page 15
ETIBREAK Moulded case circuit breakers and switch disconnectors - 16

Low voltage moulded case circuit breakers with residual current protection Main advantages: ■ Combined protection against overloads, short circuits and earth leakage integrated in one device ■ The new EB2R save the space ■ The EB2R has the same dimensions and fixing as the EB2 MCCBs ■ The EB2R eliminates the need for either an external relay with current transformers or add-on block ■ Residual current is adjustable ■ Earth leakage protection time delay is adjustable ■ Wide range of accessories (as MCCB - only shunt/undervoltage trip units can not be fitted to EB2R) Note: all internal and...

Open the catalog to page 16
ETIBREAK Moulded case circuit breakers and switch disconnectors - 17

Note: all internal and external accessories can be used with EB2R - only exceptions are DA shunt trip unit and NA undervoltage trip unit (cannot be fitted to EB2R) etibreak Residual current monitor and pre trip module Residual current monitor and pre trip module (optional) ■ normally open alarm contact (2A, 250V AC) closes on detection of residual current. Alarm treshold is adjustable. ■ Green LED indicates voltage is present ■ Red LED provides visual indications of residual current. ■ Can be configured to provide trip + alarm or alarm only. ■ Remote trip terminals allow tripping by...

Open the catalog to page 17
ETIBREAK Moulded case circuit breakers and switch disconnectors - 18

AccessoriesInternal accessoriesetibreak Undervoltage trip for EB2, ED2 125-630 important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Undervoltage trip for EB2, ED2 125-630AF - Time Delay Important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Time delay of500ms Time delay units are fitted to the outside of MCCBs Undervoltage trip for EB2, ED2 400-630AF only 4p Important note: The...

Open the catalog to page 18
ETIBREAK Moulded case circuit breakers and switch disconnectors - 19

important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Time delay of 500ms Time delay units are fitted to the outside of MCCBs Undervoltage trip for EB2, ED2 1250-1600AF - Time Delay Important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Time delay of 500ms Time delay units are fitted to the outside of MCCBs etibreak Auxiliary & Alarm switch for EB2, ED2 125-1600 Important note: The shunt trip unit DA and undervoltage trip unit NA cannot be mounted in the same breaker Important note: The...