Text version of the page
0.8 mm MicroStac Connectors Electrical and Mechanical Characteristics
1 Row and 2 Row TypesStandard 6, 12 and 50Number of Pins Technical data IEC 60512 test 2aContact resistancecontact – contact 500VIEC 60512 Dielectric strength Has to be determined accordingto client-specific using case (degree of environmental pollu-
tion) according to IEC 60664IEC 60664Voltage ratingCTI-250IEC 60112Comparative figure of voltage0,4mmAir –and creepage distanceBy ambient temperature:20°C 1,6 A
70°C 1,3 A
100°C 0,8 AIEC60512test 5bCurrent rating-55/125 °CBearing and operating tem-perature area-55/125/21DIN EN 60068-1test bClimate Category Ω IEC 60512 test 3aInsulation resistance< 10 m >
4 M Ω 6 cont.: 12 N max.12 cont.: 24 N max.
50 cont.: 100 N max.IEC 60512 test 13bInsertion and withdrawalforce> 10 mating cyclesIEC 60512 test 9aMechanical operation(mating cycles)< 1 µsIEC 60512 test 2eContact disturbance (whileshock halfsine)50g11 msIEC 60512 test 6cShock halfsine< 1 µsIEC 60512 test 2eContact disturbance (whilevibration sine)10 – 2000 Hz20gIEC 60512 test 6dVibration > 10 >
6Catalog E 07448410/07Edition 8www.erni.com