You may also be interested in
Weight transmitter, Transmitter, Amplifier
Text version of the page
Model CellMate
Vishay Tedea-Huntleigh
Document Number: 12072 www.vishaymg.com
Revision 12-Jul-07 1
Load Cell Mounting Assembly for
Models 355, 3410, 3420 and 3510
FEATURES
• Simplifies load cell installation on tanks, silos and other
weighing vessels
• 3 models suitable for load cell models 3510, 3410, 3420,
and 355
• Accepts load cells ranging in capacity from 5 to 5,000kg
• Permanent protection against load cell damage
• Grounding strap provides low resistance path to minimize
electrical potentials
• Provision for thermal expansion, contraction and lift-off due
to winds or collision
• Cable gland protector prevents cable damage
• Stainless steel construction
• Internal jack for load cell easy installation and replacing
• Ball and cup version also available
DESCRIPTION
The CellMateTM is a superior load cell
mounting assembly that dramatically
simplifies load cell installation.
A perfect solution to vessel weighing in
diaries, chemical, bottling and food
processing plants, stainless steel
CellMateTM mounts can be used on tanks,
silos and many other weighing vessels and
applications.
The CellMateTM family of mountings also
provides an unparalleled degree of
protection for load cells and maintains a
permanent load cell safety system,
reducing load cell damage and plant
down-time.
CellMateTM assemblies are available in
three models with weighing capacities from
5 to 5000kg in stainless steel. Standard
dimensions and hole sizes provide for fast
and easy placement of load cells. Ideal for
use with Vishay Tedea-Huntleigh’s line of
hermetically sealed shear and bending
beam load cells. CellMateTM includes an
internal jack which enables users to install
the fittings on silos or tanks with or without
load cells.
APLICATIONS
• Hostile environments
applications
• Process control
• Batch weighing
• Silo/hopper weighing
• Belt scale weighing
OUTLINE DIMENSIONS in millimeters
80
VIEW A
A
IN JACKED UP POSITION
FOR LOAD CELL REMOVAL
86
2 SLOTS MILLED Ø11 WIDE IN BASE PLATE
FOR M10 UNC FIXING BOLTS
2 HOLES DRILLED Ø11 WIDE IN BASE PLATE
FOR M10 FIXING BOLTS
56
18 24 14
96
13 13
70
2 HOLES TRAPPED
Ø11 IN
CAPPLATE FOR
M12 BOLTS
OR M10
THROUGH BOLTS
42 76 64
132
25
IN WEIGHING POSITION
Model 355
(5 - 500kg)
78 MIN
CLEARANCE FOR
LOAD CELL REMOVAL
|
|