Model 3540 Deflection Gages (Deflectometers) - Epsilon Technology - #1

/ 1


catalogue search
Model 3540 Deflection Gages (Deflectometers) - Epsilon Technology
P. 01
Page:
Model 3540 Deflection Gages (Deflectometers) - Epsilon Technology


See other catalogues for Epsilon Technology
You may also be interested in

Signal conditioner, Calibrator, Load cell, Extensometer


Text version of the page
I 3540 Deflection Gages (Deflectometers)
Epsilon
Technology Corp
Widely used for measuring deformations in three and
Ordering Information
Features
• Full bridge, 350 ohm strain gaged design for compatibility with nearly any test system.
• All standard units meet existing ASTM class B-2 and ISO 9513, class 0,5 requirements for accuracy.
• Rugged, dual flexure design for improved performance.
• Includes high quality foam lined case.
• Comes with an adjustable magnetic base for easy mounting.
• General purpose deflection sensor covers many test requirements.
• Spring loaded arm detaches to prevent damage from overtravel.
Specifications
Excitation: 5 to 10 VDC recommended, 12 VDC or VAC max.
Output: 2 to 4 mV/V, nominal, depending on model
Linearity: 0.15% to 0.25% of full measuring range, depending on model
Temperature Range: Standard (-ST) is -40 °C to +100 °C (-40 °F to 210 °F)
Cable: Integral ultra-flexible cable, 8 ft. (2.5 m) standard
Operating Force: 50 g typical
Options
Connectors to interface to nearly any brand test equipment Shunt calibration module (see page 96) Arm orientation
Model 3540 Available Versions: ANY combination of measuring range and temperature range listed below is available.
four point bend tests, on compression tests and for a
Measuring Range
DESIGNATION
LINEARITY
-005T
0.050"
0.15%
-015T
0.150"
0.15%
-025T
0.250"
0.20%
-050T
0.500"
0.20%
-100T
1.000"
0.25%
METRIC
-001M
1.0 mm
0.15%
-004M
4.0 mm
0.15%
-006M
6.0 mm
0.20%
-012M
12.0 mm
0.20%
-025M
25.0 mm
0.25%
variety of general purpose deformations.These strain
gaged devices come with a magnetic base for easy
mounting.
Deflection is measured with a single arm with an attached spherical contact tip, similar to those on a dial indicator. The full bridge strain gaged construction provides an electrical output compatible with any electronics designed for a strain gaged transducer.
The magnetic base furnished with the gage can be mounted to the desired reference surface, whether flat or round. The tip can then be positioned to measure the defor­mation encountered during the test. The magnetic base can only be used for low and standard temperature testing. Elevated temperature testing requires additional support considerations.
All models feature a spring loaded arm that can break free in the event of excessive displacement, protecting the gage from damage. The upper arm exerts a small spring force against the specimen, which is sufficient to allow dynamic cyclic testing if desired, yet light enough in force to avoid influence on the test.
These units come standard with the arm set to measure downward deflections when oriented in the upright position. They can be used upside down or in any orientation. They may also be configured with the extensometer arm spring loaded downward. Specify this if desired. Note that the measuring ranges listed are total displacement.
*
Model Number 3540-
Temperature Range
-265 °C to 100 °C (-450 °F to 210 °F) -40 °C to 100 °C (-40 °F to 210 °F) -40 °C to 150 °C (-40 °F to 300 °f)1 -40 °C to 175 °C (-40 °F to 350 t)1'2 -265 °C to 175 °C (-450 °F to 350 °F)V
-LT
-ST
-HT1
-HT2
-LHT
Magnetic base not for high temperature use 50 °C (125 °F) max Short term use to 200 X (400 X) acceptable
Example: 3540-012M-ST: 12.0 mm measuring range, standard temperature option (-40 °C to 100 °C)
3540 with magnetic base included.
3540 with 1" measuring range.
Da]
.63
Contact Epsilon for your special testing requirements.
3540 WITHOUT MAGNETIC BASE
DIMENSIONS: [mm] inches
72
73

pageCatalog pdf di En 2012-05-19-09