Dampener Sizing Examples Typical Shock Absorber Applications

Overview

Shock Absorber Sizing Examples EXAMPLE 18: STEP1: Application Data ω Ι ) Known Intertia = 885 in-lbs/sec. ) Angular Velocity = 2 rad/sec.(T) Torque = 2,750 in-lbs. ( STEP 2:Calculate kinetic energy STEP 5: Calculate total energy per hour: not applicable, C=1 E Vertical Rotation with Known Intertia Aided by Gravity (w/Torque) (W) Weight = 220.5 lbs. ( E
K =( Ι x ω
2 )/2E
2 K =(885 x 2 )/2E
T C = E
T x CE
K = 1,770 in-lbs.
T C = 1,780.4x 100E
2 T C = 178,040in-lbs/hr. (C/G) Center-of-Gravity = 12 in.( STEP 3: Calculate work energy θ ) Starting point fromtrue vertical = 120 F
D = [T – (W x C/G x Sin ( θ
θ – Ø)]/R
S STEP 6: Calculate impact velocity and confirm selection V = R (Ø) Angle of rotation at impact = 30° (R

Ëš

F
D =[2,750 – (220.5 x 12 x Sin (120 º –30 º )]/10F
D = 10.4 lbs.E
S x ω = 10 x 2 = 20 in./sec.Model OEM 1.15M x 1 is adequate(Page 24).
S ) Mounting radius = 10 in.(C) Cycles/Hr = 100
W = F
D x S = 10.4 x 1 = 10.4 in-lbs. STEP 4: Calculate total energy per cycle E
T = E
K + E
W = 1,770 + 10.4E
T = 1,780.4 in-lbs/cyc. E EXAMPLE 19: STEP1: Application Data ω ) Angular velocity = 2 rad./sec.(T) Torque = 2,750 in-lbs. (A) Length = 40 in. (R STEP 2:Calculate kinetic energy Vertical Roation Pinned at Center (w/Torque)STEP 4: Calculate total energy per cycle (W) Weight = 220.5 lbs. ( K=.289 x (A
2 2 + B
2 )
0.5 K=.289 x (40
T = E
K + E
W = 153.8 + 275 E
2 + 2
2 )
0.5 = 11.6 in. I = (W/386) x K
T = 428.8 in-lbs./cycle I = (220.5/386) x 11.6
2 ) Mounting radius = 10 in.(B) Thickness = 2 in. (C) Cycles/Hr = 100
2 = 76.9 in-lb/sec
2 STEP 5: Calculate total energy per hour E
S E
K = ( Ι x ω )/2E
2 K = ( 76.9 x 2 )/2E
T C = E
T x CE
K = 153.8 in-lbs.Assume Model OEM 1.0 is adequate (Page 21).
T C = 428.8 x 100E
T C = 42,880 in-lbs./hr. STEP 6: Calculate impact velocity and confirm selection V = R STEP 3: Calculate work energy
S x ω = 10 x 2 = 20 in./sec.Model OEM 1.0 is adequate. F
D = T/R
S F
D =2,750/10F
D = 275 lbs.E
W = F
D x S = 275 x 1 = 275 in-lbs.
www.enidine.com Email: industrialsales@enidine.comTel.: 1-800-852-8508 ext. 111Fax: 1-716-662-0406

12

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-120
pdf-page pdf di En 2008-10-41-12