LCL Take-Apart - DeSuperheating
2Pages

{{requestButtons}}

Catalog excerpts

LCL Take-Apart - DeSuperheating - 1

Thermal Expansion Valves The LCL Take-Apart series is a desuperheating (Liquid Injection) valve used in conjunction with hot gas bypass to prevent excessive suction line superheat. LCL valves can be used for interstage cooling in compound systems. • Stainless steel power element eliminates corrosion and prevents valve failure • Take-Apart construction for easy field service Interchangeable, replaceable cages for versatility External superheat adjustment Interchangeable body flanges Interchangeable power assemblies • Maximum working pressure: Nomenclature example: LCLE 2 B 5 FT 3/8 x 1/2 ODF S/T LCL Valve Series De-Superheating Liquid Injection Take-Apart Capacity Nominal NOTE: This is not system capacity Refrigerant Code Capillary Tube Length Inlet x Outlet Connection Sizes Connection Type E=External (Omit for Internal) (Contact Application Engineering for sizing) Ordering Information Description Equalizer Type Replacement Valve Guide PCN By Charge Select From Table Below A B C LCL 1 022018 022017 -LCL 2 022005 021996 045527 Internal LCL 3 055093 021987 -Same as LCL 6 047759 --TCL & LCLE 1 055096 --TCLE LCLE 2 022003 021997 -1/4””SAE External LCLE 3 021991 021985 -LCLE 4 -061054 055097 NOTE: Add charge suffix symbol “A”, “B”, or “C” based on the following table. Example: LCLE4-A LA(E)S 1/2 LA(E)S 1 LA(E)S 2 LA(E)S 3 LA(E)S 5 LCL 5 LCLE 5 LCL 8 LCLE 8 Replace with: LCL 1 LCL 2 LCL 3 LCL 4 LCL 6 LCL 6 LCLE 6 LCL 9 LCLE 9 Note: Valve sizes LCL5, LCL8, LCLE5 and LCLE8 are OBSOLETE. ( ) Denotes LA Series valve charge code. Refrigerant R-22 Required Suction Gas 45°F 65°F Emerson Climate Technologies

Open the catalog to page 1
LCL Take-Apart - DeSuperheating - 2

LCL Take-Apart – DeSuperheating Dimensional Data Thermal Expansion Valves LCL(E) Dimensional Data (in) LCL Angle Connection Size Inlet Outlet 3/8 SAE 3/8 SAE 1/2 SAE Allow 2-1/8” above valve for removal of power assembly. Remote Bulb Dimensions Capillary Tubing Length (Ft) Standard Remote Bulb Emerson Climate Technologies

Open the catalog to page 2

All Emerson Commercial & Residential Solutions catalogs and technical brochures

  1. 1E78-151

    2 Pages

  2. TLE series

    2 Pages

  3. ZZ series

    2 Pages

  4. 204CD

    2 Pages

  5. 214CB

    2 Pages

  6. 222CB

    2 Pages

  7. 314UB

    2 Pages

  8. 50RB

    2 Pages

  9. 100RB

    2 Pages

  10. 200RB

    3 Pages

  11. 200RD

    2 Pages

  12. 240RA

    2 Pages

  13. 500RB

    2 Pages

  14. 540RA

    2 Pages

  15. NXT Series

    2 Pages

  16. TFE R-410A

    1 Pages

  17. TI Series

    1 Pages

  18. A Series

    3 Pages

  19. HF Series

    2 Pages

  20. BA/BN Series

    3 Pages

  21. EX Brochure

    4 Pages

Archived catalogs

  1. Coils

    3 Pages

  2. Solenoid Valve

    25 Pages