Millennium II M22 Transmitter - Dual Channel Universal Gas Monitoring
4Pages

{{requestButtons}}

Catalog excerpts

Millennium II M22 Transmitter - Dual Channel Universal Gas Monitoring - 1

Millennium II Gas Detection Transmitter Product Data Sheet Dual Channel Universal Gas Monitoring “SMART” Gas Detector Series The Millennium II (M22) dual channel universal transmitters have been engineered from the ground-up to include the innovative features that managers and operators in the field demand, while providing rock solid day-to-day operation, even in the most extreme conditions. The Millennium II redefines what you expect from a fixed gas detection solution. SMART Sensor Technology — Compatible with All Sensor Types (Infrared, Catalytic Bead, Electrochemical, and NE-MOS) -55°C to +85°C Temperature Range Lowest Power Consumption Available Diagnostics with Event and Data Logging Full Wide Voltage Range Allows For Greater Stability and System Compatibility Intuitive Menu System, Simple Set-up/Calibrations Field Selectable Gas Curves and Ranges and Match All Sensor Types on a Single Mix Transmitter, Greater Coverage and Flexibility Long Range (+2000ft.) Sensor Separation SMART Sensor Technology Superior OLED Display The transmitter can be fitted with a wide range of toxic and/ or combustible gas sensors. SMART (Self Monitoring Analysis and Reporting Technology) sensors are pre-calibrated and easily connected to the transmitter which recognizes a newly fitted sensor, automatically uploading it’s specific configuration profile. The only full graphic OLED display available, easy to read in all ambient lighting conditions and operates down to -55°C! Analog, Relay, Modbus® RS485 RTU Multiple communication protocols allow the M22 to work seamlessly with your new or existing system. Digital Communications Sensor and transmitter continuously communicate digitally, giving you the confidence of stable, accurate protection with fast response times even over long separation distances. Global Certifications The Millennium II is approved to international hazardous area safety standards for operation and performance. Easy To Use Menus English, French, Portuguese or Spanish display languages included. The full text menu makes installation, operation and calibration simple. No manual necessary! PMS - Uncoated Field-proven Sensor Innovations All of our sensors are engineered to be fast and reliable with field-proven performance in the harshest industrial conditions possible. These include Nano-Enhanced Metal Oxide Semiconductor (NE-MOS) toxic gas sensors that do not “fall asleep” and a full range of fast response Electrochemical toxic gas sensors. For combustible gas detection, poisonresistant Catalytic Bead technology with SensorGuard, which greatly prolongs sensor life and Infrared sensor technology utilizing a dual beam design with no mirrors that can become contaminated (“fogged up”) or misaligned.

Open the catalog to page 1
Millennium II M22 Transmitter - Dual Channel Universal Gas Monitoring - 2

Millennium II Gas Detection Transmitter Product Data Sheet “SMART” Gas Detector Series Electrical Power Consumption Voltage Range ORDERING INFORMATION 2.4W @ 24 or 12 Vdc (average - varies by sensor types/quantities) Ordering Matrix Example: M22-AD-S (Transmitter - Output - Enclosure Material) Conduit Opening Dual Channel - Analog & Relay & Modbus Enclosures Available: Aluminum (-A) Stainless Steel (-S) -55°C to +85°C (-67°F to +185°F) Certified Operating Range Dual Channel - Analog & Modbus Relative Humidity Dual Channel - Analog & Relay Organic LED (OLED), Power/Status LED’s Dual Channel...

Open the catalog to page 2
Millennium II M22 Transmitter - Dual Channel Universal Gas Monitoring - 3

Millennium II Gas Detection Transmitter Product Data Sheet Separation Boxes & Accessories “SMART” Gas Detector Series SEPARATION BOXES Class 1, Division 1, Groups BCD - Class 1, Zone 1 -- Enclosure rated NEMA 4X, IP67 (See man-0081 for full specifications) JB-MPD-S Digital Output - Stainless Steel Digital Output - Aluminum A Aluminum Housings Stainless Steel Housings F Aluminum Housings Stainless Steel Housings 103 Stainless Steel Housings 100 Universal duct mount assembly with 1M inlet sampling pipe - Stainless Steel Universal duct mount assembly with 1.5M inlet sampling pipe - Stainless...

Open the catalog to page 3
Millennium II M22 Transmitter - Dual Channel Universal Gas Monitoring - 4

Millennium II Gas Detection Transmitter Product Data Sheet FCD PDS M22 Gas Detection Transmitter November 2013 Emerson Process Management Calgary, Alberta, Canada T1Y7J7 BLOC LIKE SHARE ©2013 Emerson Process Management. All rights reserved. Emerson Process Management, Rosemount Analytical, and Net Safety Monitoring are marks of Emerson Process Management group of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be...

Open the catalog to page 4

All Emerson Automation Solutions - ROSEMOUNT catalogs and technical brochures

  1. TankRadar Pro

    32 Pages

  2. SW-300

    4 Pages

  3. DL8000

    12 Pages

  4. AMS Suite

    16 Pages

  5. Line Card

    2 Pages

Archived catalogs