Millennium II Dual Channel Gas Detector
4Pages

{{requestButtons}}

Catalog excerpts

Millennium II Dual Channel Gas Detector - 1

Millennium II Gas Detection Transmitter Product Data Sheet BCR-0049-00-008 August 2012 M22 Transmitter Dual Channel Universal Gas Monitoring “SMART” Gas Detector Series The Millennium II (M22) dual channel universal transmitters have been engineered from the ground-up to include the innovative features that managers and operators in the field demand, while providing rock solid day-to-day operation, even in the most extreme conditions. The Millennium II redefines what you expect from a fixed gas detection solution. SMART Sensor Technology — Compatible with All Sensor Types (Infrared, Catalytic Bead, Electrochemical, and NE-MOS) -55°C to +85°C Temperature Range Lowest Power Consumption Available Diagnostics with Event and Data Logging Full Wide Voltage Range Allows For Greater Stability and System Compatibility Intuitive Menu System, Simple Set-up/Calibrations Field Selectable Gas Curves and Ranges and Match All Sensor Types on a Single Mix Transmitter, Greater Coverage and Flexibility Long Range (+2000ft.) Sensor Separation SMART Sensor Technology Superior OLED Display The transmitter can be fitted with a wide range of toxic and/ or combustible gas sensors. SMART (Self Monitoring Analysis and Reporting Technology) sensors are pre-calibrated and easily connected to the transmitter which recognizes a newly fitted sensor, automatically uploading it’s specific configuration profile. The only full graphic OLED display available, easy to read in all ambient lighting conditions and operates down to -55°C! Analog, Relay, Modbus® RS485 RTU Multiple communication protocols allow the M22 to work seamlessly with your new or existing system. Digital Communications Sensor and transmitter continuously communicate digitally, giving you the confidence of stable, accurate protection with fast response times even over long separation distances. Global Certifications The Millennium II is approved to international hazardous area safety standards for operation and performance. Easy To Use Menus English, French, Portuguese or Spanish display languages included. The full text menu makes installation, operation and calibration simple. No manual necessary! PMS - Uncoated PMS - Coated CMYK Field-proven Sensor Innovations All of our sensors are engineered to be fast and reliable with field-proven performance in the harshest industrial conditions possible. These include Nano-Enhanced Metal Oxide Semiconductor (NE-MOS) toxic gas sensors that do not “fall asleep” and a full range of fast response Electrochemical toxic gas sensors. For combustible gas detection, poisonresistant Catalytic Bead technology with SensorGuard, which greatly prolongs sensor life and Infrared sensor technology utilizing a dual beam design with no mirrors that can become contaminated (“fogged up”) or misaligned.

Open the catalog to page 1
Millennium II Dual Channel Gas Detector - 2

Millennium II Gas Detection Transmitter Product Data Sheet BCR-0049-00-008 August 2012 M22 Transmitter Specifications “SMART” Gas Detector Series Electrical Power Consumption Voltage Range 10.5 – 32.0 Vdc (HART: 18 – 32 Vdc) EMC Compliance ORDERING INFORMATION 2.4W @ 24 or 12 Vdc (average - varies by sensor types/quantities) EN 50270:2006 per EMC directive 2004/108/EC Display M22-A Temperature 0-99% RH non condensing Ordering Matrix Example: M22-AD-S (Transmitter - Output - Enclosure Material) Enclosure Metallurgy Aluminum or 316 SS Conduit Opening Dual Channel - Analog & Relay & Modbus...

Open the catalog to page 2
Millennium II Dual Channel Gas Detector - 3

Millennium II Gas Detection Transmitter Product Data Sheet BCR-0049-00-008 August 2012 Millennium II Series Separation Boxes & Accessories “SMART” Gas Detector Series SEPARATION BOXES Class 1, Division 1, Groups BCD - Class 1, Zone 1 -- Enclosure rated NEMA 4X, IP67 (See man-0081 for full specifications) JB-MPD-S Digital Output - Stainless Steel JB-MPD-A Digital Output - Aluminum A Aluminum Housings Stainless Steel Housings 6.3 5.9 B 160 150 5.6 5.1 F Aluminum Housings Stainless Steel Housings 5.7 5.8 C 142 130 5.4 4.6 G 145 147 2.6 2.6 D 137 117 9.7 8.9 H 66 66 2.9 2.9 E 4.1 3.9 B C D E...

Open the catalog to page 3
Millennium II Dual Channel Gas Detector - 4

Millennium II Gas Detection Transmitter Product Data Sheet Emerson Process Management Calgary, Alberta, Canada T1Y7J7 BLOG LIKE LEARN SHARE ©2012 Emerson Process Management. All rights reserved. Emerson Process Management, Rosemount Analytical, and Net Safety Monitoring are marks of Emerson Process Management group of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or...

Open the catalog to page 4

All Emerson Automation Solutions - ROSEMOUNT catalogs and technical brochures

  1. TankRadar Pro

    32 Pages

  2. SW-300

    4 Pages

  3. DL8000

    12 Pages

  4. AMS Suite

    16 Pages

  5. Line Card

    2 Pages

Archived catalogs