Cu-terminals and connectors 0.75 - 1000 mm²
Markings on Cu-connections Cu-connectionsElpress marking system for Cu-connec-tors shows logotype, conductor area and id-number for crimp die to be used. This system enables final inspection of proper die use as the die number is automatically imprintedby the dieon the crimped bar-rel. Elpress Cu-connections are produced from electrolytic 99.9% copper. Terminals and through connectors exist in a large variety of types for stranded as well as for flexible conductors. C-sleeves for earth conductor branch off also come in a large number of sizes. If a standard type is not suitable, we produce tailor made designs specific to the application.Marking of tap-off C-sleeves120 - 150/70 - 95120 - 150 = Cu-wire range,mm²KR/KRF terminals and KS/KSF connectors may beused for both stranded and flexi-ble conductors.70 - 95 = Cu-wire range,mm²Copper terminals & connectors - 19817 4(Elpress logotype) C16 - 13Cat.no.KRD terminals and KSD connectors are used for stranded conductors.Stud holes in terminal palmsKRT terminals and KST connectors equal the German "Standard types" (not DIN!) and are used for stranded conductors.Screw-dimension Hole diametertol. H13 (Ø mm)C-sleeves are used for branch-off or crossconnectionsfor mainly earth con-ductors such as for lightning protectionand earthing grids.Bycrimping Elpress terminals and con-nectors with Elpress crimp tools, connec-tions are achieved that meet the requirements of SEN 245010, BS 4579:1, VDE 0220:1, EN-IEC 61238:1whichever is applicable.Marking of tube terminals M 3 3,2 M 4 4,332(on the terminal neck) M 5 5,3 ID-no. for the hexagonal die M 6 6,4(Elpress logo) 300-16F(on the palm) M 8 8,4 M 10 10,5 300 = Cu-conductor area, mm² M 12 13 16= hole for screw M16 M 16 17 F = KRF M 20 21 M 24 25Number of crimpsNormally only one crimp per conductor end is needed up to and including 150 mm² and two crimps forlarger areas. For detailed information see crimp dietables in Chapter 10. If possiblemultiple crimps should be positioned with a few mm dis- tance from each other and from the neck end. In many cases however, overlapping crimpshave to be made for space rea-sons.Marking of connectors(Elpress logo)27ID-no. for hexagonal die185 F (possible screen area and an earth-sign)185= Cu-conductor area, mm² F = KSF Crimp sequence with two adjacent crimps.4:2Certificate FM20987ISO 9001:2000 |
|