SGR282Z
\rejays
Relay data ^^^^^
Pcb relay with forcibly guided contacts
- Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation diagonally between left and right contact side (leakage and creeping distances > 5.5mm)
- EN 50205, type B
- 2 CO contacts
- Mean coil power 1 W
- Holding power 0.31 W
30,2,12,7.
General data
Diagrams
Circuit diagram (view on relay upper side) Contact lifetime for AgCuNi
10 000
=
=
E
E
=
=
=
=
=
E
E
!
-
-
-
-
-
-
s
=
=
=
=
1
1
i
i
■s.
-
-
DC 1: 24
V
»»»
^■w 1
<*>.
AC 1: 230V
^■h 1
==
=
=
=
=
=
__
AC 1
5: 230V
w
=
=
=
1
=
-
DC 13: 24V
Zt
1000
o o o
o
X co
o to cd q_ o
"o
ö
100
TD co
SGR282Z
2
c
o
10
0.1
0.5
1.0
5.0
10
Switching current (A) ■
Double or reinforced insulation
Max. switching characteristics (acc. to DIN EN 60947-5-1 table C2): AC 15: 230V/3A, DC13: 24V/4A UL 508: C300
Maximal contact load at AC 1 with 230V: 2 contacts each with 6A
Gold contacts with 4-6ym layer thickness
When high voltages and currents are switched, the layer of gold is destroyed already after a few switching operations. Once the gold layer is damaged due to the switching of high loads, such a contact must not be used any more for signal and control current circuits.
Safe contact making is then only possible at high loads with the formation of sparks.
Load limit curve with direct current
> 50 x 106 operations
Mechanical life
CI Ó
Switching frequency, mechanical
20Hz
Response time
typically 12ms
Drop-out time***
typically 5ms
7,5
Bounce time of NO contact
typically 4ms
Bounce time of NC contact
typically 8ms
Vibration resistance 10-55Hz, AK 10g, RK 1.5g Test voltage coil/contacts 5'000Veff 1min
0 1,3
Test voltage
[mm]
4'000Veff 1min
Contact material AgCuNi
Test voltage contact open
1'500Veff 1min
Type of contact Single contact
Insulation resistance
1011 n
Rated switching capacity 250VAC 6A AC1 1'500VA
Creepage resistance
CTI 550
Electr. life AC1 (360 cycles/h) approx.100'000
Weight
approx. 20g
Inrush current max. 15A for 20ms
Mounting position
any
Switching voltage range 50 to 250 VDC/VAC
Ambient temperature
-40°C to +70°C
Switching current range* 20mA to 6A
Type of protection RT II / RT III optionally
Switching current range** 10mA to 6A
Solder bath temperature
270°C/5s
Switching capacity range* 0.12VA(W) to 1'500VA
Thermal resistance
50K/W
Switching capacity range** 0.06VA(W) to 1'500VA
Temperature limit for coil
120°C
Contact resistance (as delivered)< 100mQ / 28 V / 100mA * Guide values
** Values for AgCuNi + 4-6 urn Au
Standard coils for direct current (other voltages on request)
*** without spark suppression Insulation terms
Coil/contacts: Double or reinforced insulation
> 14mm_
Left to right contact side:
Double or reinforced insulation > 5.5mm
2
Nominal voltage VDC
Min. pick-up voltage at 20°C
Drop-out voltage at 20 °C
Nominal current in mA
Resistance in Ohm at 20 °C
Tolerance in %
5
3,75
> 0,5
181,8
27,5
± 10
6
4,5
> 0,6
166,6
36
± 10
12
9,0
> 1,2
85,7
140
± 10
18
13,5
> 1,8
66,6
270
± 10
24
18,0
> 2,4
33,3
720
± 10
48
36,0
> 4,8
20,8
2'300
± 10
60
45,0
> 6,0
13,6
4'400
± 13
110
82,5
> 11,0
11,0
10'000
± 15
c cd
Zi
U
0,1
0 50 100
Voltage (VDC) -»■
Inductive load, L/R 40 ms Resistive load
Tests, regulations
Approvals
150
200
250
SEV, UL, cUL, TÜV
Sec. 1
UL File E188953
Insulation class IEC 60664-1
250VAC
Protection class II
VDE 0106
UL 94 / V1
Fire protection requirements
Excitation voltage range
2,0
i
1,5
1,0
1
Ub
0,5
Un
0
Options, accessories
Contact material SGR282Z..VDC AgCuNi _+4 - 6um Au
2>
PCB socket, DIN rail socket Wash-resistant with O-Ring
see page 29
Ordering example
sgr282z 24vdc au6 08
Sealed RT III
on request
20
0
100
40
60
80
Type designation Coil voltage-
Ambient temperature °C
1) Max. excitation voltage with contact load < 2A
2) Min. excitation voltage (guaranteed values) without previous operation
No heat accumulation due to intrinsic heating of other components. Continuous duty 100%.
Gold plating 4 - 6um Au . Wash-resistant / with O-ring
+41 81 300 47 00 E-Mail: admin@elestarelays.com i
ELESTA relays GmbH, Elestastrasse 16, CH - 7310 Bad Ragaz, Switzerland
Phone: Fax:
+41 81 300 47 01 Internet: http://www.elestarelays.com
13
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23