Download Product catalogue 2008 - ELESTA relays - #19

/ 36


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
Pages:


See other catalogues for ELESTA relays
You may also be interested in

Relay, Safety relay, Relay socket


Text version of the page
SIM 4 Contacts
Relay data
General data
Diagrams
PCB relay with forcibly guided contacts Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) EN 50205, type A Contact mounting: SIM312 3NO/1NC SIM222 2NO/2NC Small external dimensions Mean coil power 1W Holding power 0.29W
Circuit diagram (view on relay upper side) Contact lifetime for NO contact
10 000
=
=
=
=
=
=
=
=
=
=
=
=
-
-
-
-
-
-
-
-
-
_
Z
z
z
z
r
AC 1: 2
30V
Z
Z
:
-
=
=
=
=
"*^-^
)C 1:
---^
\
*
_
=
=
=
=
=
=
=
=
AC 15: 230V
^ [I |-|-|-
-
-
-
-
nf 1 O. OA\l-
UC 3 24V
CD
co
o o o
4: 4^
1000
X co
o
CD Q_
O
"o Ö
SIM222
100
C CD O T3
Basic insulation
Double or reinforced insulation
10
0.1 0.5 1.0
Switching current (A) -
10
5.0
Max. switching characteristics
(determined acc. to DIN EN 60947-5-1 table C2):
AC 15: 230V/3A
DC 13: 24V/4A
DC 13: 24V/6A/0,1Hz
UL 508: C150/R300
Maximal contact load at AC 1 with 230V:
2 contacts each with 8A
3 contacts each with 6A
Load limit curve with direct current
> 10 x 106 operations
Mechanical life
36,1
12,5
Switching frequency, mechanical 15Hz
Response time
typically 8ms
Drop-out time**
typically 4ms
Bounce time of NO contact
typically 6ms
Bounce time of NC contact
typically 12ms
Shock resistance 16ms
NO contact > 10g
Vibration resistance
10-200Hz
NO contact > 10g
Test voltage coil/contacts
5'000Veff 1min
Test voltage
left to right contact sides
4'000Veff 1min
Test voltage
contacts as one after the other 2'500Veff 1min
Test voltage contact open
1'500Veff 1min
Insulation resistance
1011 n
Creepage resistance
CTI 250
Weight
approx. 25g
Mounting position
any
Ambient temperature
-40°C to +70°C
Type of protection
RT II
Solder bath temperature
270 °C/5s
Thermal resistance
50K/W
Temperature limit for coil
120°C
Pollution degree
2
Overvoltage category
III
26,
-4v
03 0,41 15,9
05.
255
2,8
5 |5 I 5
2,5
2,4
7,5.
„0 1,3
15,9
5
5
5
[mm]
2,8'
2,4
Contact material
AgSnO2+0,2um Au
Crest contact
Type of contact
(A)
Rated switching capacity 250VAC 8A AC1 2'000VA Electr. life AC1 (360 cycles/h) approx.100'000 Inrush current max. 20A for 20ms
c CD
Zi
Switching voltage range Switching current range*
5 to 250 VDC/VAC 10mA to 8A
0,1
0
50 100
150
200
250
Switching capacity range* 0,06VA(W) to 2'000VA Contact resistance (as delivered) <100mQ/28 V/100mA * Guide values
Standard coils for direct current (other voltages on request)
Voltage (VDC)
1) Inductive load, L/R 40 ms
2) Resistive load
Excitation voltage range
2,0
1'000A SCPD 10A _gG (pre-fuse)
Resistance to short circuiting
Nominal voltage VDC
Min. pick-up voltage at 20°C
Drop-out voltage
at 20 °C
Nominal current in mA
Resistance in Ohm at 20 °C
Tolerance in %
** without spark suppression
Insulation terms
Coil/contacts:
Double or reinforced insulation > 14mm
Left to right contact side:
Double or reinforced insulation > 5.5mm
5
3,75
> 0,5
181,8
27,5
± 10
6
4,5
> 0,6
166,0
36
± 10
Contacts in one row: Basic insulation
12
9,0
> 1,2
85,7
140
± 10
Tests, regulations
Approvals SEV, UL, cUL, TUV
21
15,75
> 2,1
46,6
450
± 10
24
18,0
> 2,4
40,0
600
± 10
48
36,0
> 4,8
20,8
2'300
± 10
60
45,0
> 6,0
16,6
3'600
± 13
UL File E18895 Sec. 3
110
82,5
> 11,0
9,6
12'000
± 15
Insulation class IEC 60664-1 250VAC
1,5
1,0
2/
0,5
Un
0
20
100
0
40
60
80
Ambient temperature °C ■
1) Max. excitation voltage with contact load < 2A
2) Min. excitation voltage (guaranteed values) without previous operation
No heat accumulation due to intrinsic heating of other components. Continuous duty 100%.
Protection class II
VDE 0106
Ordering example SIM 3 1 2 24VDC
Fire protection requirements_UL 94 / V0
Options, accessories
PCB socket, DIN rail socket_see page 30
_Coil voltage
Soldering tags
Number of NC contacts Number of NO contacts Type designation
ELESTA relays GmbH, Elestastrasse 16, CH - 7310 Bad Ragaz, Switzerland
Phone: Fax:
+41 81 300 47 00 +41 81 300 47 01
E-Mail: admin@elestarelays.com Internet: http://www.elestarelays.com
19

pageCatalog pdf di En 2012-05-22-29