Catalog excerpts

RS Series Catalogue Chapter-1

STEM RS Reaction Stations Equipment for parallel synthesis The STEM RS series Reaction Stations enable parallel synthesis to be carried out by offering the same controlled temperature and stirring rates at several reaction positions simultaneously. The STEM RS Reaction Stations give you a choice of: • 6 to 50 positions • Working sample columes of between 10-30ml (but up to 250ml for RS600) • Operational temperature range of ambient to 150ºC • Optional higher temperature models for up to 300ºC • Powerful stirring rate of between 400 - 2000rpm • Wide range of accessories Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 74 STEM RS Reaction Stations STEM RS600 Reaction Station STEM RS900 Reaction Station STEM RS1000 Reaction Station STEM RS2500 Reaction Station STEM RS5000 Reaction Station STEM RS9000 Reaction Station Accessories for RS series Reaction Stations Find out more! Please scan the QR/Mobile Tag with your smartphone for more information Electrothermal Catalogue

 Open the catalog to page 1
RS Series Catalogue Chapter-2

RS600, RS900, RS1000, RS2500, RS5000, RS9000 STEM RS Reaction Stations The Stem RS Reaction Stations enable parallel synthesis to be carried out by offering the same controlled temperature and stirring rates at several reaction positions simultaneously. They can be used for a wide range of applications from simple synthesis to process optimisation. The RS9000 is the exception in that it carries out controlled heating and shaking, as opposed to stirring. The STEM RS Reaction Station range accommodates sample sizes from 2ml to 250ml in a wide range of vessel sizes and heating formats. Adaptor sleeves...

 Open the catalog to page 2
RS Series Catalogue Chapter-3

STEM RS600 Key Features Reaction Station • 6 position reaction station • 57.5mm diameter vessels • Can accommodate 40mm and other diameter vessels with appropriate adaptor sleeves • Sample sizes up to 250ml • Controlled temperature range from ambient to 250ºC • Powerful stir speed from 400 to 2000rpm • Bi-directional stir speed • Manual control or external control via the The RS600 is a six position reaction station designed for 57.5mm diameter vessels (also 40mm and other diameter vessels with appropriate adaptor sleeves), and sample sizes up to 250ml. With a controlled temperature range from...

 Open the catalog to page 3
RS Series Catalogue Chapter-4

STEM RS900 Key Features Reaction Station • 10 position reaction station • 24mm/25mm diameter vessels The RS900 is a 10 position reaction station designed for 24mm/25mm diameter vessels (also 16mm and other diameter vessels with appropriate adaptor sleeves), and sample sizes from 10ml to 30ml. The unit has a controlled temperature range from ambient to 150ºC, along with a powerful stir speed from 400 to 2000rpm. • Can accommodate 16mm and other diameter vessels with appropriate adaptor sleeves • Sample sizes from 10ml to 30ml • Controlled temperature range from ambient to 150ºC • Powerful stir...

 Open the catalog to page 4
RS Series Catalogue Chapter-5

STEM RS1000 Key Features Reaction Station • 10 position reaction station • 24mm/25mm diameter vessels • Can accommodate 16mm and other diameter The RS100 is a 10 position reaction station designed for 24mm/25mm vessels with appropriate adaptor sleeves diameter vessels (also 16mm and other • Sample sizes from 10ml to 30ml diameter vessels with appropriate adaptor sleeves), and sample • Controlled temperature range from ambient sizes from 10ml to 30ml, along with a controlled temperature range from ambient to 150ºC. to 150ºC • Powerful stir speed from 400 to 2000rpm • Manual/external control via...

 Open the catalog to page 5
RS Series Catalogue Chapter-6

STEM RS2500 and RS2400 Reaction Stations Key Features • Choice of 25 position (RS2500) or 24 position (RS2400) reaction stations The RS2500 is a 25 position reaction unit & the RS2400 a 24 • 24mm/25mm diameter vessels position reaction station, designed for 24mm/25mm diameter • Can accommodate 16mm and other diameter vessels. They both accommodate 16mm and other diameter vessels with appropriate adaptor sleeves vessels with appropriate adaptor sleeves), and sample sizes from • Controlled temperature range from ambient to 10ml to 30ml. They have a controlled temperature range from ambient to 150ºC,...

 Open the catalog to page 6
RS Series Catalogue Chapter-7

STEM RS5000 Key Features Reaction Station • 50 position reaction station • 24mm/25mm diameter vessels • Can accommodate 16mm and other diameter vessels with appropriate adaptor sleeves The RS5000 is a 50 position reaction station designed • Sample sizes from 10ml to 30ml diameter • Controlled temperature range from ambient +5ºC to 150ºC and sample sizes from 10ml to 30ml. It has a controlled • Powerful stir speed from 400 to 2000rpm powerful stir speed from 400 to 2000rpm. for 24mm/25mm diameter vessels (also 16mm and other vessels temperature with range appropriate from ambient adaptor to 150ºC...

 Open the catalog to page 7
RS Series Catalogue Chapter-8

STEM RS9000 Key Features Heater/Shaker Reaction Station The RS 9000 Heater/Shaker Reaction Station can be used within a robotic workstation or as a stand-alone apparatus in the lab. On a robotic platform, heating and shaking cycles can be controlled by external software or as part of a fully automated system through the RS232/ RS485/ GSIOC ports; for standalone use, there is the additional option of controlling heating and shaking cycles via the user friendly touchscreen. The CTC panel (Capacitance Touch Control) of the touchscreen enables the temperature and shaking speeds to be changed using...

 Open the catalog to page 8
RS Series Catalogue Chapter-9

Heater/Shaker Reaction Station Safety Features The RS9000 has a thermal cut-off that eliminates runaway conditions. The 'Hot block' warning via a highly visible warning display icon alerts you to when the block temperature is above 50°C, even when the apparatus is unplugged from the power supply. The RS9000 can be stopped rapidly in case of emergency by pressing down on the front sliding door; the front display will indicate "Door Open" and immediately stop. Heating and stirring can be reset after stopping by closing the door and pressing the function key zones on the front panel to reactivate....

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.