ROGOSWKI COIL CURRENT SENSORS - 400A - Electrohms - #1

/ 1


catalogue search
ROGOSWKI COIL CURRENT SENSORS - 400A - Electrohms
P. 01
Page:
ROGOSWKI COIL CURRENT SENSORS - 400A - Electrohms


See other catalogues for Electrohms

Text version of the page
eii-Līruhim
Product Data Sheet:- 400Amps ROGOWSKI CURRENT SENSOR WITH 4-20mA OUTPUT
I Page 1 ofT
Customer part No. : —
Date :- 13.05.08 Customer: -
Rev: 01
-28.50
0 4.00mm
1+OUTPUT« J Y^DC POWER INPUT (GROUND) I- OUTPUT DC powER INPUT (POWER)
7.00
78.20
69.00
2. Technical specifications of the complete module 2.1 Terminals
Terminal Wire colour
PWR Red
GND__Black
1+__Orange
I- Brown
GENERAL TOL. ±0.5 mm
ALL DIMENSIONS r ARE IN'mm'
SCALE -NTS
FEATURES :
SPECIFICATIONS **
PARAMETERS
UOM
VALUES
Max primary Current rating (full scale)
Arms
400
Frequency Range
Hz
45 to 65
Primary current crest factor
4.0 max
Voltage (PWR to GND) Single supply,
Vdc
10 to 30
Measurement Bandwidth
KHz
14
Linearity 10 to 100% of full scale
%
Better than ±0.5
Temperature Coefficient (1)
PPM
30
Accuracy
%
2.0
Resolution
% of full scale
0.20
Power on delay until Valid output
Seconds
1.0 typical
Current loop output range
'mA
4 to 20
Burden resistance on 4-20mA loop output
Ohms
50
Dielectric strength between rogowski coil and
KVrms
4.0
primary conductor, 50Hz, for 60 seconds
Max current rating
'mA
21 @ over current
The module lead out cable
3meters, 4core, stranded, 28AWG, UL style 2464 (without shielding)
Operating Temperature for guarenteed performance
°C
-20 to +70
Operating Humidity
%Rh
40 to 95
Storage temperature
°C
-20 to +70
Storage Humidity
%Rh
40 to 95
Since the connecting cable leads are Fly leads , ensure proper connection of the wires.
** Specifications subject to change.
Electrohms Pvt. Ltd.,
#881/B, Dr. M.C Modi Hospital Road,
Basaveshwaranagar,
Bangalore - 560 086,India
Tel:+91 (80)23220025 Fax:+91 (80)23224756 www.electrohms.com e-mail: sales@electrohms.com

pageCatalog pdf di En 2012-05-22-29