Product Data sheet : Current Transformer- CT1248-RC

Date : 01.12.07 Rev : 02 Page 1 of 1 Customer: Standard Type Customer's part No.: --- MECHANICAL DIMENSIONS 9.3

Potted Surface

Ø5.0

Primary Current

Batchcode 19.0 CT1248-RC YY/XX 16.8 0.8 ± 0.05 4.5 ± 0.1 F S 12.7 ±0.5 mm Termination:- F : Finish, S : Start ALL DIMENSIONSGENERAL TOL. ARE IN 'mm' SCALE -NTS FEATURES : Low Amplitude Error & Phase Error. Encapsulated & P.C. Mountable. VALUES Current RangeAmplitude ErrorTurns RatioD C R@ 25°C Ω Ω (Resistive)0.05 – 10 Arms1 : 1500<0.2%50/60 Hz45-60 Phase Error <0.5°- 40 °C to + 70 °C.75.0 Operating Temperature Range SPECIFICATIONS **Recommended Secondary BurdenFrequency of OperationPARAMETERS
** Specifications subject to change.

Note :

Amplitude error and Phase error values are guaranteed with recommended Secondary burden. Refer to ELECTROHMS

Electrohms Pvt. Ltd.,

Tel : +91 (80) 23220025Fax: +91 (80) 23224756 #881/B, Dr. M.C Modi Hospital Road,Basaveshwaranagar,Bangalore - 560 086, IndiaProduct Design Group for use of burden other than recommended Secondary burden. www.electrohms.com e-mail: sales@electrohms.com