ENERGY EM3D T10 Three-Phase Analyzer. - ELCOTRONIC - #4

/ 4


catalogue search
P. 01
P. 02
P. 03
P. 04
Pages:


See other catalogues for ELCOTRONIC
You may also be interested in

Analyzer, Network analyzer, Relay, Energy meter, Protection relay


Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:3.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:9.00pt "Arial", sans-serif; } .font5 { font:12.00pt "Arial", sans-serif; } .font6 { font:17.00pt "Arial", sans-serif; } .font7 { font:4.00pt "Times New Roman", serif; } .font8 { font:5.00pt "Times New Roman", serif; } .font9 { font:10.00pt "Times New Roman", serif; } .font10 { font:30.00pt "Times New Roman", serif; } DATA DISPLAY PAGES ST32/144 PRINTER The EM3 Energy Analyzers are available in two versions: E~.:^.^vT; DIN rail mounted (9 modules) The analyzer can be connected directly to the ST32/144 thermal printer through the serial output RS232 TTL. The printer allows the data collected by EM3 to be printed at set intervals. In the models with memory, the printout reads: days/months/years - hours/minutes/seconds - Elcotronic srl followed by the measure of the three- and single-phase basic parameters. The symbol "#" before a parameter, means that an alarm will be activated when the parameter setpoint is exceeded. The symbol "*" before "#" means that the value is currently under alarm, i.e. has exceeded its set limits. Alarms are always positioned on the single phases; when a parameter goes under alarm conditions a printout is produced; when the alarm stops, a printout is made to testify variation. and panel mounted (144x144 mm) at the same list price. The table below shows, for each model, the standard outputs mounted on the units and the different features. When ordering, please specify the version and the model as follows: EM3-DIN-T28-232 models and internal functions EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... EM3 ... T10 T10MEM T15/AL1 T15/AL2 T15/SC1 T15/SC2 T15/AL1-SC1 T20 T22 T23 T24 T25 T26 T27/232 T27/485 T28/232 T28/485 T29/232 T29/485 T30/232 T30/485 T31/232 T31/485 T32/232 T32/485 T33/232 T33/485 T34/232 T34/485 BACK LIGHT ONLY VISUALIZATION ONLY VISUALIZATION - MEM kWh - DATE AND HOUR ALARM WITH 1 INTERNAL RELAY 3AMP ALARM WITH 2 INTERNAL RELAYS 3AMP LOAD CUTOFF WITH 1 INTERNAL RELAY 3AMP LOAD CUTOFF WITH 2 INTERNAL RELAYS 3AMP 1 INTERNAL RELAY FOR ALARM 1 INTERNAL RELAY FOR LOAD CUTOFF POSSIBLE FUTURE EXPANSIONS Printer ALARM Printer Printer ALARM Printer ALARM MEM Printer RS232 RS485 ALARM MEM RS232 MEM RS232 RS232 RS485 RS485 RS485 ALARM ALARM MEM RS232 ALARM MEM RS485 ALARM MEM RS232 MEM RS485 MEM RS232 ALARM MEM RS485 ALARM MEM Printer RS232 ALARM MEM Printer RS485 ALARM TEMP IMP RESET TEMP IMP RESET TEMP IMP RESET TEMP IMP RESET controllec paramètres BACKLIT DISPLAY ON REQUEST warning 220VAC-50Hz or 24VCC Power Supply upon request. When ordering the version with serial output, please specify if RS485 or RS232 is desired. The instrument always shows all the functions on the display, as specified in the table above. To activate outputs (e.g. alarm output) relevant EM3 must be ordered (see Table) together with the optional external module. THREE PHASE-NEUTRAL CONN. optional external modules ■ :||==; MSC485/232 Conversion module RS485/RS232 for PC connection and EM3 SoftCom software - L 2 load MR4 DIN module for alarms and/or load cutoff, 5Amp relay output - L 3 TDÛ TE1 TE2 1 temperature probe C1 2 temperature probes C1 + C2 20 +150°C Length 3 mt. 20 +150°C Length 3 mt. 230 VAC ±10% 50/60Hz ST 32/144 32-column thermal printer, panel-mounted version 144x144 mm. 12Vdc/9Vac Power Supply RST 32 Pack of 5 rolls of thermal paper for printer ST32/144 ST TRAS 9V ST32/144 Printer transformer (220V/9V-1A) C100 DIN-C-RS232 PLUG/PLUG extensionfor connection between EM3 andaccessories PLUG/9POLES extension for connection on RS232 panel 144 mm 157,5 mm Installing the EM3 Analyzer is very simple: • connect the volt cables V1 - V2 - V3 and Neutral between the EM3 connector and the mains • connect the current transformers CT1 - CT2 -CT3 between the EM3 connector and the mains • 230VAC±10% - 50Hz Power Supply 64 mm B mm 73 mm A elcotronic Edition 02/2003 Data are given as an example, only. E Technical changes can be made without notice. Via Serraglio 48 40026 Imola (Bo) Italy Tel 0542 641770 Fax 0542 641761 www.elcotronic.it info@elcotronic.it

pageCatalog pdf di En 2012-05-20-18