Load cell Technology Comparison

Property\Technology Eilersen Capacitive Technology Strain gage Technology Magnetic Force Restoration (MFR) Technology Accuracy
Medium-High MediumHigh Sampling Rate
Up to 1000 Hz Depends on manufacture Depends on manufacture Stiffness
High Low-MediumHigh Eccentric Load Stiffness
High Low-MediumMedium Available Load Rating
High HighLow Tolerance of Overloads
High Low-MediumLow Tolerance of Shock Loads
High MediumLow Electrical Installation
RS485 output Analog output RS485/RS232 output Mechanical Installation
Mechanical protection not necessary Mechanical overload and sideload protection necessary Mechanical overload and sideload protection necessary In-factory calibrated to transmit load directly in grams, kilograms or tonsSends out an analog mV/V signal Depends on manufacture Calibration Diagnostics
Integrated Diagnostics Depends on manufacture Depends on manufacture Sealing
Up to IP69K Up to IP69K Up to IP66 Required Maintenance
Minimal Depends on manufacture Depends on manufacture Warranty
3 years Depends on manufacture Depends on manufacture Visit us at www.eilersen.com info@eilersen.com