1. Catalogs
  2. EDWARDS
  3. Active Ion Gauge Controller Datasheet
video corpo

Active Ion Gauge Controller Datasheet
1 /2Pages

Active Ion Gauge Controller Datasheet

Active Ion Gauge Controller Datasheet
1 /2Pages

Catalog excerpts

Active Ion Gauge Controller Datasheet-1

ACTIVE ION GAUGE CONTROLLER RANGE 5 X 103 TO 2 X 10 11 mbar The Edwards Active Ion Gauge Controller (IGC) provides all the power, control and signal conditioning required to run one or When connected to a Edwards TIC Instrument Controller the user has full control of the ion gauge functions from the TIC front panel. This includes features such as automatic emission current selection and interlock with other gauge types. Alternatively, the IGC can be linked directly to a control system such as a PLC to give the OEM or system builder direct access to control inputs and signal outputs. • Wide measurement range - Electron beam degas versions: • Selection of head available - Choice of electron beam degas, nude or glass encapsulated, tungsten or thoriated iridium • Flexible cabling system - Ion gauge cables are available in 2 and 3m lengths including bakeable versions. Active gauge cables to link IGC and AGC are available • Vacuum interlock through an auxiliary low vacuum Active gauge - To protect the ion gauge from accidental operation at high pressure it can be interlocked through an Active Pirani or thermocouple gauge connected to the IGC or • Ratiomatic measurement system - Improved measurement accuracy - Allows soft start on filament power-up giving an added degree of filament protection • Choice of Edwards interface (EHVI) or parallel command and status port (PCSP) - EHVI: allows connection to Edwards TIC Instrument Controller - PCSP: 15 way D-type connector giving access to all control input and signal outputs

 Open the catalog to page 1
Active Ion Gauge Controller Datasheet-2

ACTIVE ION GAUGE CONTROLLER RANGE 5 X 103 TO 2 X 10 11 mbar Technical Data Power supply Input voltage range Input frequency range Main supply socket Temperature range Relative humidity (non condensing) Enclosure rating Pressure range Electron beam degas (EBEAM) Emission current Filament power supply Note: 2 head versions of the IGC will only drive one head at a time Degas power Electron beam (EBEAM) PCSP interface PCSP interface socket or EHVI (AGC) interface socket plus Auxilliary gauge socket Without rack mounting kit With rack mounting kit Electronic design Electromagnetic compatibility Active...

 Open the catalog to page 2

All EDWARDS catalogs and technical brochures

  1. SPEEDIVALVE

    2  Pages

  2. GV

    12  Pages

  3. XDD1

    2  Pages

  4. PGC

    2  Pages

  5. 8200

    2  Pages

  6. IS 320FX

    2  Pages

  7. RGA

    8  Pages

  8. EH

    2  Pages

  9. RV

    8  Pages

  10. nXDS

    12  Pages

  11. XDS series

    4  Pages

  12. T-STATION 85

    2  Pages

  13. AIM

    2  Pages

  14. WRG

    2  Pages

  15. ASG2

    2  Pages

  16. ELD500

    8  Pages

  17. iXH Dry Pumps

    2  Pages

  18. RV Pumps

    8  Pages

  19. Small EM Pumps

    12  Pages

  20. GXS Dry Pumps

    20  Pages

  21. EDP Pumps

    4  Pages

  22. CXS Dry Pumps

    12  Pages

  23. ADC Datasheet

    4  Pages

  24. nEXT Brochure

    12  Pages

  25. CXS Dry Pump

    9  Pages

  26. EV Brochure

    6  Pages

  27. Spectra G

    4  Pages

  28. iGX Dry Pumps

    4  Pages

  29. T-Station 75

    2  Pages

  30. EXT75-255DX

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.