276B & 277B Series
2Pages

{{requestButtons}}

Catalog excerpts

276B & 277B Series - 1

Conventional Fire Alarms Pull Stations 270 Series The Edwards 276B/277B series non-coded, single-action fire alarm stations are UL listed, contemporary-styled Lexan stations. The 276B series feature terminals for field wiring connections, and the 277B series use 6” (150mm) wire leads for field wiring connections. FIRE ALARMS All types are available with single pole alarm contacts that can be normally open, normally closed or a combination of both. Either a key or tool (depending on station selected) is required to reset mechanism. Where a manual station is installed on a circuit that also includes smoke detectors, a resistor can be added in series with the alarm initiating contacts on the station so the operation of the station does not extinguish alarm LEDs on operated detectors.The 276-R resistor kits permit field installation of the series resistor on applicable stations. Features and Specifications • Single action models • Single pole contacts • Terminals or wire leads for field connections • Key lock or tool reset • Break glass operation • Surface or semi flush mounting • Red finish • Contemporary styling • Rugged Lexan construction • Latch action until reset • perating temperature range: 32°F to 120°F O (0°C to 49°C) For semi flush mounting, use a standard NorthAmerican 4 inch square box with single gang plaster cover having an overall minimum depth of 2-1/4 inches (57mm). For surface mounting use a 276B-RSB surface back box. Ordering Information Contact Ratings Description 276B-11101 Single-Action Pull Station Field Connections Switch Contacts Station Reset Screw Terminals Single-pole Alarm, Open Circuit Tool Operated Screw Terminals Single-pole Alarm, Open Circuit Single-pole Alarm, Open Circuit Tool Operated Accessories Description Replacement Glass Rods Station Reset Key (supplied with all Key Reset Stations) use in stations connected to smoke detector circuits. 560 Ohms, +/-5%; 2W.

Open the catalog to page 1
276B & 277B Series - 2

Conventional Fire Alarms Pull Stations 270 Series Weights and Dimensions Approx. Shipping Weight (lb.) Front View FIRE ALARMS Cat. No. 276B Series With Optional Back Box 4" Square back box and plaster cover with single gang opening having overall min. depth of 2-1/4" (57mm) Cat. No. 277B Series Without Back Box Cat. No's. 276B & 277B Series With 276B-RSB Back Box

Open the catalog to page 2

All EDWARDS SIGNALING catalogs and technical brochures

  1. 60 Series

    1 Pages

  2. 101 Series

    4 Pages

  3. 103 Series

    1 Pages

  4. ANS Series

    3 Pages

  5. 889D 888D

    1 Pages

  6. 700 Series

    2 Pages

  7. 521 Series

    2 Pages

  8. 517T Series

    1 Pages

  9. 511C

    1 Pages

  10. 438D Series

    2 Pages

  11. 302 Series

    2 Pages

  12. 2747A L

    1 Pages

  13. 270 Series

    2 Pages

  14. 105DHISTC

    2 Pages

Archived catalogs