video corpo

G4E160-AB01-01
9Pages

{{requestButtons}}

Catalog excerpts

G4E160-AB01-01 - 1

ebm-papst Mulfingen GmbH & Co. KG Bachmuhle 2 D-74673 Mulfingen Phone +49 (0)7938 81-0 Fax+49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND INFORMATION 1.1 Hazard levels for warnings 1.2 Staff qualifications 1.3 Basic safety rules 1.4 Voltage 1.5 Safety and protective features 1.6 Mechanical movement 1.7 Emissions 1.8 Hot surface 1.9 Transport 1.10 Storage 2. INTENDED USE 1. SAFETY REGULATIONS AND INFORMATION Read these operating instructions carefully before starting work on the device. Observe the following warnings to prevent malfunctions or danger to persons. These operating instructions are to be regarded as part of the device. The device is only to be sold or passed on together with the operating instructions. These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1.1 Hazard levels for warnings These operating instructions use the following hazard levels to indicate potentially hazardous situations and important safety regulations: DANGER Indicates an imminently hazardous situation which will result in death or serious injury if the specified actions are not taken. Compliance with the instructions is imperative. WARNING Indicates a potentially hazardous situation which can result in death or serious injury if the specified actions are not taken. Exercise extreme caution while working. CAUTION Indicates a potentially hazardous situation which can result in minor or moderate injury or damage to property if the specified actions are not taken. NOTE A potentially harmful situation can occur and, if not avoided, can lead to property damage. 1.2 Staff qualifications The device may only be transported, unpacked, installed, operated, maintained and otherwise used by suitably qualified, trained and authorized technical staff. Only authorized specialists are permitted to install the device, to carry out a test run and to perform work on the electrical installation. 1.3 Basic safety rules The safety hazards associated with the device must be assessed again following installation in the final product. Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection. ; Replace loose connections and defective cables immediately. A DANGER Electrically charged device Risk of electric shock ^ When working on an electrically charged device, stand on a rubber mat. WARNING Live terminals and connections even with device switched off Electric shock Item no. 10292-5-9970 • ENU • Change 88814 • Approved 2016-08-25 • Page 1 /9

Open the catalog to page 1
G4E160-AB01-01 - 2

^ Wait five minutes after disconnecting the voltage at all poles before opening the device. CAUTION In the event of a fault, the rotor and the impeller will be energized The rotor and the impeller have basic insulation. ^ Do not touch the rotor and impeller once installed. CAUTION The motor restarts automatically when operating voltage is applied, e.g. after a power failure. Risk of injury ^ Keep out of the device's danger zone. ^ When working on the device, switch off the line voltage and ensure that it cannot be switched back on. ^ Wait until the device comes to a stop. 1.7...

Open the catalog to page 2
G4E160-AB01-01 - 3

2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device. Customer equipment must be capable of withstanding the mechanical and thermal stresses that can arise from this product. This applies for the entire service life of the equipment in which this product is installed. Intended use also includes • Conveying air at an ambient air pressure between 800 mbar and 1050 mbar. • Using the device within the...

Open the catalog to page 3
G4E160-AB01-01 - 4

Item no. 10292-5-9970 • ENU • Change 88814 • Approved 2016-08-25 • Page 4/9

Open the catalog to page 4
G4E160-AB01-01 - 5

3.2 Nominal data . With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load cycles. If you have special questions, consult ebm-papst for support. 3.4 Mounting data For screw clearance, see Chapter 3.1 Product drawing ; Secure the screws against unintentional loosening (e.g. use selflocking screws). Strength class of 8.8 screws Any further mounting data required can be taken from the product drawing. 3.5 Transport and storage conditions 4.1 Mechanical connection CAUTION Cutting and crushing hazard when removing...

Open the catalog to page 5
G4E160-AB01-01 - 6

Operating instructions 4.2 Electrical connection DANGER Voltage on the device Electric shock → Always connect a protective earth first. → Check the protective earth. DANGER Faulty insulation Risk of fatal injury from electric shock → Use only cables that meet the specified installation regulations for voltage, current, insulation material, capacity, etc. → Route cables so that they cannot be touched by any rotating parts. CAUTION Voltage The device is a built-in component and has no disconnecting switch. Protective earth contact resistance according to EN 60335 Compliance with the...

Open the catalog to page 6
G4E160-AB01-01 - 7

Item no. 10292-5-9970 • ENU • Change 88814 • Approved 2016-08-25 • Page 7 /9

Open the catalog to page 7
G4E160-AB01-01 - 8

4.5 Checking connections ; Ensure isolation from supply (all phases). ; Make sure a restart is impossible ; Check the cables for proper fit. 4.6 Switching on the device The device may only be switched on if it has been installed properly and in accordance with its intended use, including the required safety mechanisms and professional electrical hookup. This also applies for devices which have already been equipped with plugs and terminals or similar connectors by the customer. /, WARNING Hot motor housing " Risk of fire ^ Ensure that no combustible or flammable materials are located close...

Open the catalog to page 8
G4E160-AB01-01 - 9

In the event of further malfunctions, contact ebm-papst. u 5.1 Cleaning NOTE Damage to the device during cleaning Malfunction possible ^ Do not clean the device using a water jet or high-pressure cleaner. ^ Do not use any acid, alkali or solvent-basedcleaning agents. ^ Do not use any pointed or sharp-edged objects for cleaning 5.3.2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel with the appropriate technical knowledge. The product is to be disassembled into suitable components for disposal employing standard procedures for...

Open the catalog to page 9

All Ebm-papst catalogs and technical brochures

  1. RadiPac

    8 Pages

  2. RadiCal

    12 Pages

  3. G2E180-EH03-01

    10 Pages

  4. G4D225-FK10-03

    10 Pages

  5. G4D250-DC10-03

    10 Pages

  6. RadiCal

    2 Pages

  7. S FORCE

    192 Pages

  8. ECI 63

    14 Pages

  9. ATEX

    2 Pages

  10. ErP 2015

    3 Pages

  11. PLUG FANS

    76 Pages

  12. AC axial fans

    31 Pages

  13. ACmaxx

    5 Pages