Group: ebm‑papst Group
Catalog excerpts
Brushed internal rotor motors BCI series Drive solutions I Industrial drive engineering 2017-01 ebmpapst The engineer’s choice
Open the catalog to page 1Modular drive systems. Motors optional with gearhead, encoder and brake.
Open the catalog to page 2BCI motors Information about BCI motors 10 Gearheads Performax® 42 (planetary gearhead) 22 Performax® 52 (planetary gearhead) 24 Performax® 63 (planetary gearhead) 26 EtaCrown® 52 (crown gearhead) 28 EtaCrown"" 75 (crown gearhead) 30 EtaCrown®Plus 42 (crown gearhead) 32 EtaCrown®Plus 63 (crown gearhead) 34 Compactline 90 (spur gearhead) 36 Compactline 91 (spur gearhead) 38 Compactline 92 (spur gearhead) 40 Flatline 78 (spur gearhead) 42 Flatline 85 (spur gearhead) 44 Magnetic encoder system 50 Optical encoder system 52 Operating factor, lifetime,...
Open the catalog to page 3About ebm-papst. As a leader in technologies for ventilation and drive engineering, ebm-papst is in demand as an engineering partner in many sectors. With over 15,000 different products, we provide the right solution for just about any challenge. Our fans and drives are reliable, quiet and energy-efficient. Six reasons that make us the ideal partner: Proximity to our customers. The ebm-papst Group has 49 sales and 25 production sites worldwide. This means you always have a local contact who speaks You want the best solution for every project. The interrelationships your language and knows...
Open the catalog to page 4Our success story to becoming market leader and technological innovator. 1963 Elektrobau Mulfingen GmbH & Co. KG founded by Gerhard Sturm and Heinz Ziehl. 1965 Development of the first compact fan in the field of EC-/DC-technology. 1966 The ebm-papst success story started to take off with the release of the new 68 motor. 1972 The first foreign subsidiary was founded in Sweden. 1988 Gerhard Sturm receives the German Cross of Merit. 1990 The sixty millionth external rotor fan was produced. 1992 Acquisition of PAPST Motoren GmbH in St. Georgen. 1997 Purchase of the Landshut plant (mvl). 2003...
Open the catalog to page 5Gearheads (page 22) Performax® 42 (planetary gearhead) (page 22) • Performax® 52 (planetary gearhead) (page 24) Performax® 63 (planetary gearhead) (page 26) EtaCrown® 52 (crown gearhead) (page 28) • EtaCrown® 75 (crown gearhead) (page 30) EtaCrown®Plus 42 (crown gearhead) (page 32) • EtaCrown®Plus 63 (crown gearhead) (page 34) Compactline 90 (spur gearhead) (page 36) • • Compactline 91 (spur gearhead) (page 38) Compactline 92 (spur gearhead) (page 40) Flatline 78 (spur gearhead) (page 42) • Flatline 85 (spur gearhead) (page 44) Encoder systems (page 50) PMG 2-2/2-12...
Open the catalog to page 7Information about BCI motors. – DC motor with permanent magnets – Support with the accreditation of products in different economic – Power range between 13 and 93 watts – High power density realized in a compact design – High overload capacity – Highly efficient – Mechanical commutation through a multi-piece collector areas and markets – As an experienced and competent partner we would be happy to support you – Possible approvals include CE, CCC, UL, CSA, EAC or other certification marks. – Customer-specific winding layout – Winding insulation as per insulation class B – Protection class IP...
Open the catalog to page 10The data in this catalog contain product specifications, but are not a guarantee of particular properties. The speed at which the motor can be operated for long periods at an ambient temperature of 40°C and with output of the nominal All information is based on the measuring conditions mentioned torque in a thermally conductive installation. It is an operating point below. Operation of motors using reference electronics at an ambient temperature of max. 40°C when attached (thermally conductive) to a free-standing steel plate of the following size: The torque that the motor can output for...
Open the catalog to page 11Rated efficiency nN [%] Indicates the ratio in % of the mechanical output power to the absorbed electrical output relative to the nominal operating point. Typically, the nominal operating point is close to the optimum efficiency. Speed at no-load operation nL [rpm] The speed that takes effect at the nominal voltage and with unloaded motor. For the DC motor, it is proportional to the applied supply voltage. The theoretical possible speed at no-load operation can, in some cases, be limited by the mechanical ceiling speed. Start-up torque MA [mNm] The torque that the motor can output for short...
Open the catalog to page 12Factory building Medical technology Railway technology
Open the catalog to page 13Direct current motor with permanent magnets made of ceramic bound ferrite Mechanical commutation through 8-piece collector Closed steel motor housing with die-cast zinc bearing flanges Operation in both directions of rotation Service life 3,000 h for continuous operation (S1) Insulation class B Protection class IP 40, optionally higher Nominal data Nominal voltage (UBN) V DC Nominal speed (nN)* rpm Nominal torque (MN)* mNm Nominal current (IBN)* A Nominal output power (PN)* W Rated efficiency, approx. (nN) % Free-running speed (nL) rpm Free-running current (IBL) A...
Open the catalog to page 14Shaft dimensions 0D (A-side) L2 (A-side) 0D (B-side) L (B-side) Standard type 5g5 20.0 mm -- -Preferred type 5 5 14.5 mm 55 15 mm * Blind holes for thread-forming screws according to DIN 7500 Permissible shaft load at nominal speed and life expectancy L10 of 3,000 h (at TU 40°C). Connection cable black GND (-) Cable end 7 ± 2 stripped and tin-coated Change of the rotating direction is possible by polarity reversal of the wires Modular construction kit Brake system Spring-applied braking BFK 457-01 (page 48) Basic motor Planetary gearhead Performax®...
Open the catalog to page 15Nominal data motor. -52.XX - Direct current motor with permanent magnets made of ceramic bound ferrite - Mechanical commutation through 12-piece collector - Closed steel motor housing with die-cast zinc bearing flanges - Operation in both directions of rotation - Service life 3,000 h for continuous operation (S1) - Insulation class B - Protection class IP 40, optionally higher BCI 52.30 A00 BCI 52.30 B00 BCI 52.60 A00 BCI 52.60 B00 Nominal voltage (UBN) Nominal speed (nN)* Nominal torque (MN)* Nominal current (IBN)* Nominal output power (PN)* Rated efficiency, approx. (nN) Free-running...
Open the catalog to page 16All Ebm-papst catalogs and technical brochures
-
EC centrifugal fans RadiCal
76 Pages
-
AC Motors
16 Pages
-
514 F
4 Pages
-
BCI
60 Pages
-
ECI Series
84 Pages
-
VHD146
5 Pages
-
It’s All a Matter of TechNiQ.
16 Pages
-
Centrifugal fans and blowers
616 Pages
-
Condensing boiler technology
48 Pages
-
AC motors
11 Pages
-
RadiPac EC centrifugal fans
136 Pages
-
RadiCal EC centrifugal fans
172 Pages
-
Axial fans (version 2007)
436 Pages
-
ECI motors
24 Pages
-
VDC-3-49.15
8 Pages
-
ECI 63 modular drive series
14 Pages
-
BG motors
5 Pages
-
BCI motors
28 Pages
-
AC axial fans - HyBlade®
48 Pages
-
EC axial fans - HyBlade®
48 Pages
-
AC / EC Transformer Fans
36 Pages
-
Compact fans for AC and DC
269 Pages
-
Accessories for fans
23 Pages
-
AC axial fans
26 Pages
-
ACmaxx fans
22 Pages
-
Specials for fans
18 Pages
-
DC centrifugal fans
72 Pages
-
DC axial fans
64 Pages
-
AC and DC voltage compact fans
268 Pages
-
RadiPac EC centrifugal fans
104 Pages
-
RadiCal EC/AC centrifugal fans
184 Pages
-
EC/AC axial fans - AxiCool
56 Pages
-
VarioDrive C
9 Pages
-
Plug fans with EC motor
76 Pages
-
GreenTech: The Green Company.
16 Pages
Archived catalogs
-
Condensing boiler technology
48 Pages