video corpo

AC / EC Transformer Fans
36Pages

{{requestButtons}}

Catalog excerpts

AC / EC Transformer Fans - 2

The new AC / EC transformer fans from ebm-papst Axial fans with external-rotor motors in AC and EC technology are our world. What is new is that they are now used for transformer cooling. But then again, why not? After all, efficiency, low noise and total reliability are called for in such an application, too! And so our new AC / EC transformer fans are first choice with project and design engineers, not only when it comes to transformer cooling. Robust, quiet and speed-controlled The new transformer fans with asynchronous and EC motor drives are now also available for the more demanding...

Open the catalog to page 2
AC / EC Transformer Fans - 3

The new AC / EC transformer fans from ebm-papst Technical parameters & scope Electrical connections Distributors, agents & subsidiaries

Open the catalog to page 3
AC / EC Transformer Fans - 4

Technical parameters & scope High standards for all ebm-papst products Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best possible product for your application. Careful monitoring of the market ensures that technical innovations are reflected in the improvements of our products. Based on the technical parameters listed below and the ambience you want our product to operate in, we here at ebm-papst can always work out the best solution for your specific application. General performance parameters Service life Any deviations from...

Open the catalog to page 4
AC / EC Transformer Fans - 5

Measuring station Sound power level All acoustic data is established in keeping with DIN 45635 and ISO The direction of air flow is given as follows: 3744/3745 to accuracy class 2 and given as A-weighted. To measure sound power level Lw 10 microphones are distributed on an enveloping surface on the suction side of the fan under test (measuring set-up as per DIN 45635 T38). Measuring conditions ebm-papst products are measured under the following terms and conditions: - axial fans in the wall ring and without guard grille - Depending on the mounting situation, there can be deviations from the...

Open the catalog to page 5
AC / EC Transformer Fans - 6

Left: Climate cabinet Right: Salt spray test equipment Mechanical strain / performance parameters Chemo-physical strain / performance parameters All ebm-papst products are subjected to comprehensive tests complying For information on chemo-physical strain, please turn to our brochure with the normative specifications. In addition to this, the tests also reflect „Protecting fans against water and the elements“: the vast experience and expertise of ebm-papst. Vibration test Vibration tests are carried out in compliance with - vibration test in operation according to DIN IEC 68, parts 2-4 -...

Open the catalog to page 6
AC / EC Transformer Fans - 7

Left: Extended-time test room Middle: Shock test Right: Condensate water test Legal and normative directives The products described in this catalogue are designed, developed and produced in keeping with the standards in place for the relevant product and , if known, the conditions governing the relevant fields of application. Standards The AC products described here comply to EN 60034-1. EC products are in keeping with the applicable specific standard. EMC In general, our EC products comply with the following EMC standards: - interference emission EN 61000-6-3 - interference immunity EN...

Open the catalog to page 7
AC / EC Transformer Fans - 8

Power input Start-up current Current draw Blade angle Nominal data Nominal voltage – Material: Guard grille made of steel, zinc-plated and plastic coated, RAL 9006 Wall ring made of sheet steel, hot-dip galvanised and plastic coated, RAL 9006 Screwed on fan blades made of sheet aluminium, varnished, RAL 9005 Asynchronous external-rotor motor made of die-cast aluminium, varnished, RAL 9005 Terminal box made of die-cast aluminium, varnished, RAL 9005 – Direction of air flow: “A” – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (according to EN 60529) – Insulation...

Open the catalog to page 8
AC / EC Transformer Fans - 9

Blade angle Motor protection: TOP brought out (on terminal strip) Cable exit: lateral via terminal box Protection class: I (according to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (according to EN 60034)

Open the catalog to page 9
AC / EC Transformer Fans - 10

Power input Start-up current Current draw Blade angle Nominal data Nominal voltage – Material: Guard grille made of steel, zinc-plated and plastic coated, RAL 9006 Wall ring made of sheet steel, hot-dip galvanised and plastic coated, RAL 9006 Screwed on fan blades made of sheet aluminium, varnished, RAL 9005 Asynchronous external-rotor motor made of die-cast aluminium, varnished, RAL 9005 Terminal box made of die-cast aluminium, varnished, RAL 9005 – Direction of air flow: “A” – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (according to EN 60529) – Insulation...

Open the catalog to page 10
AC / EC Transformer Fans - 11

Blade angle Motor protection: TOP brought out (on terminal strip) Cable exit: lateral via terminal box Protection class: I (according to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (according to EN 60034)

Open the catalog to page 11
AC / EC Transformer Fans - 12

Power input Start-up current Current draw Blade angle Nominal data Nominal voltage – Material: Guard grille made of steel, zinc-plated and plastic coated, RAL 9006 Wall ring made of sheet steel, hot-dip galvanised and plastic coated, RAL 9006 Screwed on fan blades made of sheet aluminium, varnished, RAL 9005 Asynchronous external-rotor motor made of die-cast aluminium, varnished, RAL 9005 Terminal box made of die-cast aluminium, varnished, RAL 9005 – Direction of air flow: “A” – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (according to EN 60529) – Insulation...

Open the catalog to page 12
AC / EC Transformer Fans - 13

Blade angle Motor protection: TOP brought out (on terminal strip) Cable exit: lateral via terminal box Protection class: I (according to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (according to EN 60034)

Open the catalog to page 13
AC / EC Transformer Fans - 14

Start-up current Current draw Power input Blade angle Nominal data Nominal voltage – Material: Guard grille made of steel, zinc-plated and plastic coated, RAL 9006 Wall ring made of sheet steel, hot-dip galvanised and plastic coated, RAL 9006 Screwed on fan blades made of sheet aluminium, varnished, RAL 9005 Asynchronous external-rotor motor made of die-cast aluminium, varnished, RAL 9005 Terminal box made of die-cast aluminium, varnished, RAL 9005 – Direction of air flow: “A” – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (according to EN 60529) – Insulation...

Open the catalog to page 14

All Ebm-papst catalogs and technical brochures

  1. AC Motors

    16 Pages

  2. 514 F

    4 Pages

  3. BCI

    60 Pages

  4. ECI Series

    84 Pages

  5. VHD146

    5 Pages

  6. AC motors

    11 Pages

  7. ECI motors

    24 Pages

  8. VDC-3-49.15

    8 Pages

  9. BG motors

    5 Pages

  10. BCI motors

    28 Pages

  11. AC axial fans

    26 Pages

  12. ACmaxx fans

    22 Pages

  13. DC axial fans

    64 Pages

  14. VarioDrive C

    9 Pages

Archived catalogs