AC axial fans - 1

ACmaxx / GreenTech EC-Compact fans AC axial fan overview AC axial fans

Open the catalog to page 1
AC axial fans - 2

Technical information Product line The renowned ebm-papst AC fans are used when DC voltage is not AC fans with sleeve bearings are powered by Class E insulated motors. available. The AC range of fans is based on experience gained from Fans with ball bearings are equipped with Class B, E or F insulated decades of development activity, millions of units in series production and competence in innovation of a world-wide technological leader. Type of protection A wide range of fans for AC operation is presented in this catalogue. In All fans are equipped with type of protection IP 20 as...

Open the catalog to page 2
AC axial fans - 3

Information DC axial fans Axial fans for AC operation ACmaxx / GreenTech EC-Compact fans Spee d sig nal Hum idity prote ction IP > = IP 54 IP > = IP 68 Salt fog p rotec tion Page Sinte c ball sleeve b bear earing ings s/ Sleeve bearings Ball bearings Overview of technically feasible designs

Open the catalog to page 3
AC axial fans - 4

Temperature range Nominal data Type Nominal speed Sound power level Sound pressure level Nominal voltage Input power – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Sintec sleeve bearings Ball bearings Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via 2 single wires grounding lug for M4 x 8 Mass: 490 g Note: Please note our new ACmaxx series. With identical mounting dimensions and...

Open the catalog to page 4
AC axial fans - 5

Series 8000 TV Ø 76 x 37 mm – Possible special versions: Impeller: Die-cast aluminium (See page 12) Mounting bracket: Metal - Protection against moisture Direction of air flow: Exhaust over mounting bracket - Protection against salt fog Direction of rotation: Clockwise, seen on rotor - Type of protection: IP 54 / IP 68 Connection: Via 2 single wires Mass: 370 g Temperature range ACmaxx / GreenTech EC-Compact fans Lead wires The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise has been measured with an orifice...

Open the catalog to page 5
AC axial fans - 6

Nominal voltage Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Nominal data Type Guard grilles from p. 238 – Possible special versions: (See page 12) - Protection against moisture Housing: Die-cast aluminium Impeller: Mineral-reinforced plastic PA Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 Mass: 280 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series...

Open the catalog to page 6
AC axial fans - 7

Nominal voltage Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Nominal data – Possible special versions: (See page 12) - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via 2 single wires grounding lug for M4 x 8 Mass: 420 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages,...

Open the catalog to page 7
AC axial fans - 8

Sound pressure level Sound power level Guard grilles from p. 238 Nominal voltage Nominal data Temperature range Nominal speed – Possible special versions: (See page 12) - Protection against moisture Input power Housing: Die-cast aluminium Impeller: Mineral-reinforced plastic PA Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 Mass: 320 g Note: Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. See page...

Open the catalog to page 8
AC axial fans - 9

Nominal voltage Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range – Possible special versions: (See page 12) - Speed signal - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Nominal data Type – Optionally available: Variants with strengthened mounting flanges and customizable single strands Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Intake over struts Types 4890 N and 4840 N exhaust over struts Direction of rotation: Clockwise, seen on...

Open the catalog to page 9
AC axial fans - 10

Nominal voltage Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Nominal data Guard grilles from p. 238 – Possible special versions: (See page 12) - Speed signal - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68 Housing: Die-cast aluminium Impeller: Painted sheet steel Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 x 8 Mass: 540 g Note: Please note our new ACmaxx series....

Open the catalog to page 10
AC axial fans - 11

Series 4600 TZ Ø 108 x 37 mm – Possible special versions: Impeller: Die-cast aluminium (See page 12) Mounting bracket: Metal - Protection against moisture Direction of air flow: Exhaust over mounting bracket - Protection against salt fog Direction of rotation: Clockwise, seen on rotor - Type of protection: IP 54 / IP 68 Connection: Via 2 single wires Mass: 430 g Sintec sleeve bearings Ball bearings Sound pressure level Temperature range Nominal voltage Nominal speed ACmaxx / GreenTech EC-Compact fans The air flow and noise level of fans without external housing depends on the installation...

Open the catalog to page 11
AC axial fans - 12

Housing: Die-cast aluminium Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Counter-clockwise, seen on rotor Connection: Via 2 flat plug 2,8 x 0,5 mm grounding lug for M4 x 6 Mass: 570 g – Possible special versions: (See page 12) - Protection against moisture Nominal voltage Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Guard grilles from p. 238 Nominal data

Open the catalog to page 12

All Ebm-papst catalogs and technical brochures

  1. AC Motors

    16 Pages

  2. 514 F

    4 Pages

  3. BCI

    60 Pages

  4. ECI Series

    84 Pages

  5. VHD146

    5 Pages

  6. AC motors

    11 Pages

  7. ECI motors

    24 Pages

  8. VDC-3-49.15

    8 Pages

  9. BG motors

    5 Pages

  10. BCI motors

    28 Pages

  11. ACmaxx fans

    22 Pages

  12. DC axial fans

    64 Pages

  13. VarioDrive C

    9 Pages

Archived catalogs