xEnergy - Design-verified Switchgear System - 1

xEnergy Main Design-verified Switchgear System Catalogue 2017 Powering Business Worldwide

Open the catalog to page 1
xEnergy - Design-verified Switchgear System - 2

Contents xEnergy Main - Product philosophy Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx Sample text for tenders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx System description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx Room and space requirements Power sections XP Power sections, power distribution boards up to 5000A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx...

Open the catalog to page 2
xEnergy - Design-verified Switchgear System - 3

xEnergy Main product features • Enclosures for side-by-side and stand-alone cabinets • Degree of protection IP31 or IP55 • Main busbars up to 5000 A • 2 Main busbar systems are possible in each section • Clear separations into functional areas from form 1 to form 4 to provide even better protection for people and equipment • Widths of 425, 600, 800, 850, 1000, 1100, 1200 and 1350 mm • Height 2000 mm • Color RAL 7035 (other colors upon request) • Network types TN-C, TN-C-S, TN-S, TT, IT • Type-tested switchgear assemblies in accordance with IEC/EN 61439 • Optimized for 3 and 4 pole...

Open the catalog to page 3
xEnergy - Design-verified Switchgear System - 4

Incoming supplies, outgoers and couplings up to 5000 A • cable connection from the top and bottom • busbar positions rear-mounted - bottom/top mounted or running under the top panel • section height 2000 mm / section depth 400/600/800/1000 (1000 = 800+200) mm • internal separations up to Form 4 Air circuit breakers IZM series 26 and series IZMX16/40 • widths of 425/600/800/1000/1100/1200/1350 mm • fixed or withdrawable • 3 or 4 poles • with a second busbar suitable as a coupling section • 630 - 5000 A • Form 4 • I P31, IP55 with IZM-XDT protective cover • suitable for drill-free cable...

Open the catalog to page 4
xEnergy - Design-verified Switchgear System - 5

XF - Outgoing sections - Fixed design • Outgoers with circuit breakers PKZ, NZM, FAZ, switch fuse units and fuse switch disconnectors up to 630 A • for busbar positions at the rear - top/bottom or running under the top panel • section height 2000 mm / section depth 400/600/800 mm Outgoing sections for outgoers up to 630 A in Form 2 • widths of 800/1000/1200 mm • module widths of 425 and 600 mm • 3 or 4 poles • Form 2 • I P31/55 • consistent mounting height of switchgear • circuit breakers suitable for use with plug base • single-wing section door up to 800/1000 mm, 2-wing door for 1200 mm •...

Open the catalog to page 5
xEnergy - Design-verified Switchgear System - 6

Outgoing sections for switch fuse units (load disconnector units) up to 630 A (SSL) • widths of 600/800/1000/1200 mm • suitable for rear-mounted main busbar HSS • horizontal and vertical position of fuse switch disconnector strips is possible • can be installed while energized (fuse strips) • I P31 • outgoers are possible downwards and upwards • Form 4 • operation from outside • dropper bar selectable from 800-1600 A Outgoing sections - Removable (plug-in module) design • widths of 800/1000/1200 mm • module width 600 mm • can be equipped to meet requirements of Form 2 to 4 / up to Type 7 •...

Open the catalog to page 6
xEnergy - Design-verified Switchgear System - 7

Empty sections for individual mounting units • fitting systems for modular installation devices (IVS, EP, Profit ...) • i ndividual mounting units fixed on mounting plates • control technology - suitable for installation of mounting plates as high as the section, or of split ones • section height 2000 mm • section depths of 400/600/800 mm • section widths of 425/600/800/850/1000/1100/1200/1350 mm • I P31/55 Standards/regulations Apply Cu according to Ambient temperature °C Relative humidity % Protective measure Degree of protection 1) Internal partition Rated insulation voltage Ui V...

Open the catalog to page 7
xEnergy - Design-verified Switchgear System - 8

xEnergy Main Switchboards Tender text · Ready to connect, steel-encapsulated low-voltage switchgear system in multiple control panel design with type-tested installation systems to ICE/EN 61439-1 (VDE 0660 part 500), IEC/EN 61439-2 (VDE 0660 part 600-2). · All transport units feature removable lifting eyebolts. · The following descriptions are calculation-related and contractual elements. They are to be considered with the descriptions of the individual systems and the equipment, even when they are not mentioned in detail. · Cabinet systems consisting of individual add-on sections of the...

Open the catalog to page 8
xEnergy - Design-verified Switchgear System - 9

Busbar Rated current le (Cu cross-sections) Rear-mounted (side view) Busbar Rated current le (Cu cross-sections) Top-mounted (side view) Busbar area Switchgear area | additional busbar area for 5000 A F:T«N Powering Business Worldwide

Open the catalog to page 9
xEnergy - Design-verified Switchgear System - 10

xEnergy Main Switchboards Table of Contents - Ordering Section xEnergy Main Switchboards General overview enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page xx Main busbar located at the “rear“ XP = Power sections IZMX16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IZMX40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IZM63 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Open the catalog to page 10
xEnergy - Design-verified Switchgear System - 11

xEnergy Main Switchboards Individual components Basic components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fitting kits for XP sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories for XP sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Busbars/connection systems and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fitting kits - outgoing sections . . . . . . . . . . . . . . . . . ....

Open the catalog to page 11

All Eaton catalogs and technical brochures

  1. xEnergy Basic

    176 Pages

  2. xEnergy Light

    140 Pages

  3. Data Networks

    94 Pages

  4. Cable glands

    34 Pages

  5. Crouse hinds

    272 Pages

  6. Cam Switches T

    256 Pages

Archived catalogs