|
catalogue search
|
You may also be interested in
Switchgear, Emergency stop, Position switch, Rotary switch, Software
Text version of the page
7/54 Technical dataTechnical data 7/55 DV6 vector frequency invertersDV6 vector frequency invertersMoeller HPL0213-2004/2005 Moeller HPL0213-2004/2005 DV6-340-22K DV6-340-30K DV6-340-37K DV6-340-45K DV6-340-55K DV6-340-75K DV6-340-90K DV6-340-110K DV6-340-132K General Standards EN 50178, IEC 61800-3, EN 61800-3 incl. A11 EN 50178, IEC 61800-3, EN 61800-3 incl. A11Ambient temperature Operating temperature°C -10 to +40 at rated current Ie without derating, up to 50 at a reduced pulse frequency of 2 kHz and output current reduced to 80% -10 to +40 at rated current I e without derating, up to 50 at a reduced pulse frequency of 2 kHz and output current reduced to 80% I e I e Storage, transport°C -25 – +70 -25 – +70Mechanical shock resistance Vibration and impact, max. 5.9 m/s 2 (0.6 g) at 10 to 55 Hz Vibration and impact, max. 2.94 m/s 2 (0.3 g) at 10 to 55 HzPollution degree VDE 0110 Part 2, pollution degree 2 VDE 0110 Part 2, pollution degree 2Climatic proofing Class 3K3 according to EN 50178 (non-condensing, average relative humidity 20 to 90 %) Class 3K3 according to EN 50178 (non-condensing, average relative humidity 20 to 90 %)Altitudem DF5, DF6 frequency invertersDV5, DV6 vector frequency inverters DF5, DF6 frequency invertersDV5, DV6 vector frequency inverters 0 – 1000 above sea level 0 – 1000 above sea levelMounting position Vertically suspended Vertically suspendedFree surrounding areas 100 mm above and below, 50 mm on each side 100 mm above and below, 50 mm on each sideEmitted interference IEC/EN 61800-3 (EN 55011 group 1 class B) IEC/EN 61800-3 (EN 55011 group 1 class B)Noise immunity IEC/EN 61800-3, industrial environment IEC/EN 61800-3, industrial environmentInsulation resistance Overvoltage category III according to VDE 0110 Overvoltage category III according to VDE 0110Leakage current to PEmA > 3.5 (according to EN 50178) > 3.5 (according to EN 50178)Degree of protection IP 20 (NEMA 1) IP 20 (NEMA 1)Contact protection Finger and back-of-hand proof (BGV A2) Finger and back-of-hand proof (BGV A2)Protective isolation from switching circuitry Safe isolation from the mains. Double basic isolation (according to EN 50178) Safe isolation from the mains. Double basic isolation (according to EN 50178)Protective measures Overcurrent, earth fault, overvoltage, undervoltage, overload, overtemperature, electronic overload protection: Overcurrent, earth fault, overvoltage, undervoltage, overload, overtemperature, electronic overload protection: J monitoring and PTC input (thermistor or thermostat) J monitoring and PTC input (thermistor or thermostat)Heat dissipation at rated operational current I e W 115 1550 1900 2300 2800 3750 4500 5500 6500Dimensions (w x h x d)mm 256 x 396 x 210 310 x 540 x 202.2 390 x 550 x 255.2 390 x 550 x 255.2 390 x 550 x 255.2 390 x 700 x 275.2 390 x 700 x 275.2 480 x 740 x 293.2 480 x 740 x 293.2Weightkg 12 20 30 30 30 60 60 80 80 Power section Rated operational voltageV AC 400 400 400 400 400 400 400 400 400Rated voltage U e V 3 AC 342 – 528 V g 0 % 3 AC 342 – 528 V g 0 %Supply frequencyHz 50/60 (47 -0 % to 63 +0 %) 50/60 (47 -0 % to 63 +0 %)Mains current U i = 400 V AC three-phase I A 53 63 83 99 121 164 194 239 286Alternative DC supply U DC V DC 420 – 760 420 – 760 420 – 760 420 – 760 420 – 760 420 – 760 420 – 760 420 – 760 420 – 760Modulation method Sensorless vector control, pulse width modulation (PWM) Sensorless vector control, pulse width modulation (PWM)Switching frequency 5 kHz, adjustable from 0.5 to 15 kHz 5 kHz, adjustable from 0.5 to 15 kHzOutput voltageV 3 AC U e 3 AC U e 3 AC U e 3 AC U e 3 AC U e 3 AC U e 3 AC U e 3 AC U e 3 AC U e Output frequencyHz 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400 0.5 – 50, max. 400Frequency resolutionHz 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint values 0.1, with digital setpoint values/maximum frequency/1000 with analog setpoint valuesFrequency error threshold at 20 °C g 10 K g 0.01 % of maximum frequency for digital reference values, g 0.2% of maximum frequency for analog reference values g 0.01 % of maximum frequency for digital reference values, g 0.2% of maximum frequency for analog reference valuesMax. rated operational current I e A 48 58 75 90 110 149 176 217 260Permissible overcurrent 150 % for 60 s/200 % for 0.5 s, every 600 s 150 % for 60 s/200 % for 0.5 s, every 600 sTorque during start 200 % at 0.5 Hz (sensorless vector control mode) 200 % at 0.5 Hz (sensorless vector control mode)Apparent power at 400 VkVA 33.2 40.1 51.9 62.3 76.2 103.2 121.9 150.3 180.1Apparent power at 480 VkVA 39.9 48.2 62.3 74.8 91.4 123.8 146.3 180.4 216.1Standard operation at 150 % overloadAssigned motor rating (4-pole ASM) 400 VkW 22 30 37 45 55 75 90 110 132460 VHP 30 40 50 60 75 100 125 150 175 Notes If the frequency inverter is to be installed in an enclosure, control panel or similar housing, the ambient temperature T a is taken to be the temperature inside this enclosure or control panel.All rating data of the power section is based on a switching frequency of 5 kHz (default setting) and an ambient temperature of +40°C, for operation of a four-pole three-phase asynchronous motor. |