|
|
See other catalogues for EAO
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | TECHNICAL DETAILS | | | | | | | | | | Emergency-stop | | | | | | | | | | Conventional free air thermal current | | Ith = 5 A, as per EN IEC 60947-5-1 the maximum current In continuous operation and at ambient temperature must not exceed the quoted maximum values | | | | | | Switching system | | The double-break switching system can be supplied for the following switching functions: | | | | | | | | | | | | | | | | | | 1 Normally closed, 2 Normally closed, 1 Normally closed + 1 Normally open. | | | | | | | | | | | | | | Switch rating | | Switch rating AC with silver contact (gold plated), service category AC-15, as per EN IEC 60947-5-1 Voltage: 120 VAC 240 VAC Current: 3 A 1.5 A Switch rating DC for silver contact (gold plated), service category DC-13, as per EN IEC 60947-5-1 (inductive) Voltage: 12 VDC 24 VDC 48VDC 60VDC 125VDC 250VDC Current: 5 A 4 A 2.1 A 1.7 A 0.55 A 0.27A | | | | | | The Normally closed contacts have forced opening according to EN IEC 60947-5-1 | | | | | | | | | | | | | | Material | | | | | | | | | | Perfect fit | | | | | | Connection cable | | Polyvinylchloride (PVC), operating temperature up to +65°C. Degression curve for higher current and temperature on request Polybutylenterephthalate (PBT), as per UL94 V0 (red items) | | | | | | | | | | | | | | | | | | Recommended minimum operational data | | Silver contacts (gold plated) Voltage: 1 VAC/DC Current: 1 mA | | | | | | Lens | | | | | | | | | | Mounting made easy. | | | | | | | | | | | | | | Actuator housing | | Polyamide (PA66), as per UL94 V0, Flat ribbon cable cover Polyamide (PA 6.6), as per UL94 V0 | | | | | | | | | Electric strength | 500 VAC, 50 Hz, 1 min, as per DIN IEC 60512-2 | | | | Rated conditional short-circuit current | 1000 A, type of short-circuit unit 6 A gL/gG, as per EN IEC 60947-5-1 | | | | Protection class | Class II, as per EN IEC 60947-5 | | | | Overvoltage category Class II, as per EN IEC 60947-1 | | | | Degree of pollution | Class 3, as per EN IEC 60947-1 | | | | Environmental conditions | | | | Storage temperature | -25°C to +85°C | | | | Operating temperature | -25°C to +65°C | | | | Front protection | IP 65, as per EN IEC 60529 | | | | Shock resistance | (semi-sinusoidal) max. 150 m/s2, pulse width 11 ms, 3-axis, as per EN IEC 60068-2-27 | | | | Vibration resistance | (sinusoidal) max. 100 m/s2 at 10 Hz to 500 Hz, 10 cycles, 3-axis, as per EN IEC 60068-2-6 | | | | Climate resistance | Damp heat, cyclic : 96 hours, +25°C / 97% +55°C / 93% relative humidity as per EN IEC 60068-2-30 Damp heat, steady: 56 days, +40°C / 93% relative humidity as per EN IEC 60068-2-78 Dry heat: 96 hours, +70°C as per EN IEC 60068-2-2 Low temperature: 96 hours, -40°C as per EN IEC 60068-2-1 Saline mist: 96 hours, +35°C in chemical solution NaCI, as per EN IEC 60068-2-11 | | | | Approvals | CE Declaration of Conformity UL SEV RoHS compliant | | | | | | | | | | | | | | | | | | | | | | | | | Material of contacts Sliver alloy gold plated | | | | | | | | | | Mechanical characteristics | | | | | | | | | | Mounting hole | | 22.5 mm dla. as per EN IEC 60947-5-1 with anti-twist device | | | | | | | | | | Mount alongside other Series 84 products. | | Adaptable Adaptable to PCBs of different heights using flying leads. Customisable Can be supplied with variety of cable lengths and connectors. Compatible Use in combination with full range of EAO Series 84 pushbuttons and indicators. | | | | | | | | | | | | | | | | | Terminals | Terminals 2.8 x 0.8 mm (solderable) CuSn6 tin-plated Flat ribbon cable 2, 4 or 6 wires 0.35mm2 (AWG 22) | | | | Tightening torque | Fixing nut 80 Ncm | | | | Actuation force | 22 N ±4 N | | | | Actuation travel | Approx. 4 mm to release the internal operation part | | | | Mechanical life | >50.000 cycles of operations | | | | Panel strength | Standard mounting 1 to 4mm. With protection collar 1 to 3mm | | | | Electrical characteristics | | | | Standards | The devices comply with: EN IEC 60947-5-1, EN IEC 60947-5-5 (Emergency-stop), DIN EN ISO 13850 | | | | Illumination | LED red with pole reversal, constant current source Operation voltage: 5 VDC to 30 VDC Current consumption: 9.7 mAto 12.4 mA | | | | Rated operational voltage | Ue = 250 VAC, as per EN IEC 60947-1 | | | | Rated insulation voltage | Ui = 250 V, as per EN IEC 60947-1 | | | | Rated impulse withstand voltage | Uimp = 2.5 kV, as per EN IEC 60947-1 | | | | Contact resistance | New state: 50 mQ, as per DIN IEC 60512-2-3 | | | | Isolation resistance | >1011 Q between the opened contacts at 500 VDC, as per DIN IEC 60512-2-10 | | | | Electrical life | Inductive: >50.000 cycles of operations, as per EN IEC 60947-5-1 Voltage: 120 VAC 240 VAC 125 VDC 250 VDC Current: 3 A 1.5 A 0.55 A 0.27 A Resistive: >50.000 cycles, reduced load | | | | ■ 1 | Voltage: 1 VAC/DC 42 VAC/DC Current: 100 mA 200 mA | | | | | | | | | | | | | | | | | | | | | The Emergency-stop switch can be mounted in a front plate with a thickness of between 1 and 4mm. It has a low behind-panel depth of 13.5mm (max) and can be safely and easily adapted to PCBs of different heights. Importantly, the Series 84 Emergency-stop requires no additional assembly because of its 'monoblock' design. The Series 84 range includes 22.5mm pushbuttons and indicators protected up to IP67. They are suited to a range of industrial applications and guarantee reliable switching even of very light loads. For Series 84 pushbutton and indicator data please contact your local sales office. | | | | | | <9 | | | | | | | | | | | | | | J | | | | | | | | | | | | | | www.eao.com | | | | | | eao | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|