T E C H N I C A L S P E C I F I C A T I O N
<5>2S
BExBGL1D ATEX EEx L.E.D Hazardous Area Beacon / Status Light
warning signals
BExBGLI D : EEx d IIC T4 (Tamb. -50 to +55°C) EEx d IIC T5 (Tamb. -50 to +40°C)
ATEX approved
Suitable for Zone 1, 2, 21 & 22 Gas Groups IIC IIB & IIA Array of 32 High Output L.E.D's. Colours: Amber, Blue, Green and Red. Total of 9 operation modes: 4 rotating configurations 4 flashing configurations Steady mode for indicator / status applications 3 stage beacon Rem otely selectable 2nd and 3rd stage modes Voltages : 24vdc (10-50vdc); 24vac; 115vac; 230vac Borosilicate glass dome with optically enhanced prosmatic lens cover BExBGL1D : IP67
Enclosure material : Marine grade LM6 Aluminium Chromated & powder coated finish - good resistance to humidity and salt spray environments. Stainless Steel guard. Colour available : Red (RAL3000) Operating temperature : -50 to +55°C (EExd IIC T4) -50 to +40°C (EExd IIC T5) Storage temperature : -50 to +70°C Large range of certified end of line resistors. Weight : DC:2.45kg AC: 2.75kg KEMA Certificate number : 00ATEX2006 X
BExBGLID
Flameproof & Dust ignition proof industrial beacons
Zones 1, 2, 21 & 22
© M2G/DEExdllCT4 T105X <£> II 2G/D EExd IICT5 T95°C
Installation Features.
• Very large termination area.
• Dual M20 ISO cable gland entries (supplied with one stopping plug).
• Ratchet adjustable stainless steel 'U' bracket for positive adjustment under harsh conditions.
• IN & OUT terminals
• Terminals accept 0.5 to 4.0mm2 cables.
• Line monitoring : Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor, or diode within EExd enclosure (dc versions)
Input voltages and current consumption for the BExBGLID beacon:
Voltage :
24vdc
48vdc
115vac 50/60Hz
230vac 50/60Hz
24vac 50/60Hz
Voltage range :
10-50vdc
10-50vdc
+/-10%
+/-10%
+/-10%
Current mA :
400mA
230mA
140mA
70mA
380mA
HI 111
Al dimensions are in millimetres.
Also available :
• BEx(D)S110 & 120 EEx d & EEx de sounder • units.
• Programmable versions with 45 •
BEx(D)L15 & 25 watt EEx d & EEx de loudspeakers.
BEx(D)TS110 & BExTBG05 EEx d Telephone ringers and beacons.
BEx(D)A110 & A120 EEx d & EEx de Voice Annunciation units. BExBG EEx d & EEx de 10 & 15 Joule Xenon beacons
tones and 4 stages.
Page 1 of 2