Tube sensor TLS100

Description

The TLS100 tube sensor works on the capacitive measuring principleand detects the presence of a liquid in a plastic tube. These plastic tubes may also be mounted as a by-pass on a compensator in order to signal the required medium level in containers.The sensor is simply snapped onto the tube at the ideal level of themedium and provides versatile usage for a wide range of applications in medical equipment, the food stuffs industry etc.The sensor can additionally be fixed by means of the two mountinglugs to ensure a tight fit on the tube.

TLS100 (cable version) Ordering information Technical data

(TUambient temperature= 25C, operating voltage UB= DC 24 V)

2

Type

Operating data

TLS100 tube sensor (DC 9...36 V) Media

Operating voltage U

B

DC 12/24 V (DC 9...36 V)

W water (other liquids upon request)

Power consumptiontypically 8 mAOutput currentmax. 1 A LSS minus switching (or HSS plus switching); short-circuit-proof and overload protected over the entire temperature

Process connection/tube diameter A10 mounting clips/10 mm A15 mounting clips/15 mm A25 mounting clips/25 mm Function

range, with free-wheeling diode.Voltage drop at output

A Minimum OC(open circuit principle) B Maximum OC(open circuit principle) C Minimum RC(closed circuit principle)

transistor< 200 mV at 1 A Response delay of output signaltypically 500 ms (red LED lighted when

D Maximum RC (closed circuit principle) Output signal L LSS (minus switching)

outputis switched)

H HSS (plus switching)

Reverse polarity protectionfitted between plus and minus poleShort circuit and overload protectionreset of output and autoreset after

Response delay
(1) 500 ms 3 3 s

remedy of short circuitSwitch point with vertical mounting positionadjustable via potentiometer; switch point must lie between the two

Cable ConnectionA Cable (type: LVCC, AWG 24, 3 x 0.25 mm
2 ) 2 m (standard)
(2) B Connector M8 IEC 60957-5-2 3-pole
(3) Specification of medium (option)

mounting clips

xxx factory pre-set

Visual indicationred LED lighted when output is switched Switching point hysteresisvertically mounted: typically < 3 mm

TLS100 -WA10AL0 - A 2 mxxx ordering example

Medium temperature-20 C...+90 C

(1) Other delay periods upon request.

Ambient temperature-20 C...+80 C

(2) Other lengths upon request.
(3)

Storage temperature-20 C...+80 C

Cable type 25 required see accessories.

Vibrationto be defined Protection classIP65 (standard)Materials:sensorsaluminium AlMg 3, coated housingultramid epoxypolyurethaneConnection:CableLVCC, AWG 24, 3 x 0.25 mm

2

, length min. 0.1 m ConnectorM8 IEC 60947-5-2 3-poleMounting:mounting lug ( 3.4 mm) Caution:

The switch point is factory pre-set so as to lie exactly between thetwo mounting clips. When readjusting the switch point, pleaseobserve that it again lies between the two clips. Markinglaser marking / labelEMC requirementsCE logo in accordance with EMC directive89/336/EWG In the event of extreme conducted interferences we recommend the negative

A mass surface in the proximity (< 10 mm) may influence the switchpoint and may necessitate a readjustment.

For outdoor use we recommend mounting the level sensor TLS100 in a protective enclosure so as to avoid substantial fluctuation of themedium temperature and condensation between the capacitor plates. signal to be grounded via a 100 nF capacitor. Dimensions 59 x 39.5 x 20 mm Massapprox. 50 g (without cable) Issue A www.e-t-a.com 2 - 7

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
pdf-page pdf di En 2008-10-42-14