Catalogue excerpts

The ControlPlex® Rack is an intelligent and if required remotely controllable 2U power distribution system made of aluminium in a closed housing, protected against brush contact featuring an extremely compact design. The system has been especially designed for the selective protection of systems with minus supply (DC -48 V or DC -60 V) which are widely used in communication engineering. In order to avoid voltage dips of switch-mode power supplies in the event of overload or short circuit, protection is effected by means of intelligent, short-circuit current limited electronic circuit protectors. The plug-in type terminal design of the loads and a system design allowing extension in operation help to significantly reduce installation and maintenance time. PDB Power-D-Box® 19" (supplied standard), with ETSI reversible flange - 19" Protected pole N negative pole protected Module CP ControlPlex® Rack xx Number of load channels (total) Anon-redundant design R redundant design (two supply entries, with main and load terminals on the rear) Main terminals Ron the rear F on the front load terminals R_ on the rear F on the front Version _A BUS 2 revision 2 ControlPlex® Rack: PDB -N- CP 09 A-RR-Ax:Supply current max. 150 A Load current max. 30 A with 9 load channels PDB -N- CP 09 A-FF-Ax: Supply current max. 100 A Load current max. 30 A with 9 load channels PDB -N- CP 09 A-RF-Ax: Supply current max. 150 A, Load current max. 30 A with 9 load channels PDB -N- CP 19 A-RR-Ax: Supply current max. 200 A Load current max. 30 A with 19 load channels PDB -N- CP 18 R-RR-Ax:Supply current max. 2 x 150 A Load current max. 30 A with 2 x 9 load channels • Designed for plug-in type electronic circuit protectors type ESX300-S with short-circuit limitation and extended status indication, expandable in operation. Current per load channel 2 A...24 A • Extremely compact installation depth 175 mm with terminals on the front and 205 mm with rear-side terminals • With slot for signalling or control interface sub-assembly • Use of industrially manufactured power distribution modules -protected against brush contact • Supplied with blind covers • Other versions available on request, e.g. with back-up fuses, various terminal connectors and cross sections, customised marking etc. Application    modular power distribution system for short circuit current limited DC -48 V / DC -60 V applications 19" Power-D-Box®    mength: 84 HP (462.72 mm) height: 2U (88.90 mm) material: aluminium Plug-in type circuit    ESX300-S - 300 - xx A protectors    (with ELBus® interface) Alarm Interface Plug-in type group    RSI10-xxx-A signalling interface    or Plug-in type control    RCI10-xxx-A interface Rated voltage    DC -48 V...-60    V Total current    - 2x150 A with redundant design and line entry on the rear - 200 A with non-redundant design and double line entry on the rear - 100 A with non-redundant design and line entry on the front Ambient temperature -20 °C to +60 °C (without condensation) Supply terminals    terminal on the    rear: screw terminals, cable cross section 16 mm2...50 mm2 terminals on the front: screw terminals, cable cross section 4 mm2...25 mm2 Load terminals    terminal on the rear: plug-in type 2-pole screw terminals with mating connector, cable cross section 0.5 mm2...6 mm2 terminals on the front: plug-in type 3-pole high current SUB-D connector, cable cross section 2.5 mm2...10 mm2, mating connector (not supplied with product): see accessories Ground terminal    M6 studs, always on the rear CE marking    to EMC directive (in connection with ESX300-S) Conformity    compliant with EN60950-1 / UL60950-1

 Open the catalogue to page 1

ControlPlex® Rack Schematic diagram – non-redundant design non-redundant design supply A Schematic diagram – redundant design redundant design

 Open the catalogue to page 2

ControlPlex® Rack Dimensions – connection from the front (PDB-N-CP 09A-FF-x) 515 (ETS) 1:2 cable grip set (optional) cable guide supply cable grip set (optional) cable guide loads Dimensions – connection from the rear (PDB-N-CP xxy-RR-x) 515 (ETS) 482.6 (19") 531.4 (ETS) cable grip set (optional) cable grip set (optional) cable guide supply cable grip set (optional)

 Open the catalogue to page 3

Load SUB-D connector (suitable for front connection) X 223 189 01 Consisting of: - enclosure - 3 contacts Marking band 0.5U X 223 575 01 Consisting of: 1    0.5U stainless steel marking band with marking strips 2 screws with washers 24 moulded labels 1U marking band with cable gland X 223 576 01 Consisting of: 1 1U stainless steel marking band with marking strips and cable gland 4 screws with washers 24 moulded labels All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness,...

 Open the catalogue to page 4

Technical data (Tamb = 25 °C, UB = DC -48 V) The electronic circuit protector ESX300-S has been designed for protection and monitoring systems in telecommunications. Focus application of this device is the minus switching of loads widely used in telecommunications in power supply systems with rated voltage DC -48 V and DC -60 V. The additionally available overcurrent protection, realised by means of electronic current limitation and electronic disconnection, reliably prevents the destruction of electronic sub-assemblies or load lines by overload or short circuit. In addition, the electronic current...

 Open the catalogue to page 5

• Status LEDs (red/green): • ELBus® interface (optional) • Potential-free signal contacts (optional) Table 1: LED status indication

 Open the catalogue to page 6

ESX300S for ControlPlex® Rack Schematic diagram Fuse Fail-Save electronic control system Time/current characteristics Minus (-) LINE Connection diagram (pin assignment) 1,40 1,50 ... times rated current electronic current limitation typically begins in at 1.2 x IN. This means: under all overload conditions (independent of power supply and load circuit resistance) typically 1.2 times rated current is applied until disconnection. The trip time varies between 10 ms and 30 s depending on the multiple of the current rating. Without the current limitation getting into effect at typically 1.2 x IN there...

 Open the catalogue to page 7

All E-T-A catalogues and technical brochures

  1. PC10IO

    2 Pages

    En
  2. PC10PN

    4 Pages

    En
  3. PC10PB

    4 Pages

    En
  4. VS201-CP

    2 Pages

    En
  5. High Power-D-Box

    4 Pages

    En
  6. SVS14

    6 Pages

    En
  7. SVS15

    8 Pages

    En
  8. SVS18

    6 Pages

    En
  9. 1140-E

    4 Pages

    En
  10. 1110

    2 Pages

    En
  11. 129-L11-H-KF

    2 Pages

    En
  12. 127

    4 Pages

    En
  13. 104

    4 Pages

    En
  14. SVS16-PB

    6 Pages

    En
  15. SVS20

    8 Pages

    En

Archived catalogues

  1. Level Sensors

    20 Pages

    En