Built With Quality In Mind 2015 Industrial Analyzers Product Catalog

 Open the catalogue to page 1

Providing the Latest in Combustion Gas & Emissions Analyzers for Boiler, Engine, Furnace, and Other Combustion Applications Built with Quality in Mind Industrial Combustion Gas Analyzer Reliable Robust Fast Combustion Efficiency CO Sensor w/ NOx Filter Draft & Differential Pressure 2 Channel Thermometer Internal Memory (2000 Tests) Zoom Feature Pre-Calibrated, Field Replaceable Gas Sensors PC Software with Automatic Data Saving Full COLOR Graphic Display BUILT-IN Printer E Instruments International P: 215-750-1212 F: 215-750-1399 A: 402 Middletown Blvd, Ste 216 Langhorne, PA 19047

 Open the catalogue to page 2

E1500 Features BUILT-IN Printer Built with Quality in Mind Full COLOR Graphic Display Pre-Calibrated Field Replaceable Sensors Simple Menu Interface Magnetic Rubber Holster NEW! Probes & Hoses Standard: 12”, 300mm Probe, 1470˚F/800˚C max with 10’/3m Dual Hose PC Software Package with Bluetooth & USB Unbreakable Metal Connections Parameter CO H₂ Compensated w/ Built-In NOx Filter Differential Temp. Long & High Temp: 40”, 1m Probe, 2190˚F/1200˚C max, with 10’/3m Dual Hose Long: 30”, 750mm Probe, 1470˚F/800˚C max with 10’/3m Dual Hose Hose Extensions: 10’/3m Length Available Ordering Information...

 Open the catalogue to page 3

Providing the Latest in Combustion Gas & Emissions Analyzers for Boiler, Engine, Furnace, and Other Combustion Applications Built with Quality in Mind Industrial Combustion Gas & Emissions Analyzer Reliable Robust Fast Combustion Efficiency Low NOx & Total NOx Draft & Differential Pressure 2 Channel Thermometer Internal Memory (2000 Tests) Zoom Feature Pre-Calibrated, Field Replaceable Gas Sensors Dilution Pump For CO Auto-Range Measurements Up To 50,000 ppm PC Software with Automatic Data Saving Full COLOR Graphic Display BUILT-IN Printer E Instruments International P: 215-750-1212 F: 215-750-1399...

 Open the catalogue to page 4

Full COLOR Graphic Display BUILT-IN Printer Pre-Calibrated Field Replaceable Sensors Built with Quality in Mind Simple Menu Interface Magnetic Rubber Holster PC Software Package with Bluetooth & USB Unbreakable Metal Connections CO H₂ Compensated w/ Built-In NOx Filter Ordering Information Model No. E4500 with O₂, CO, NO/NOx Gas Sensors Installed, Upgradeable to 4th Gas Sensor E4500 with O₂, CO, NO/NOx, NO₂ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm E4500 with O₂, CO, NO/NOx, SO₂ Gas Sensors & CO Dilution Auto-Range to 50,000 ppm E4500 with O₂, CO, NO/NOx, CxHy (HC) Gas Sensors & CO Dilution...

 Open the catalogue to page 5

E5500 Portable Industrial Flue Gas & Emissions Analyzer Providing the latest in Combustion Gas & Emissions Analyzers for Boiler, Engine, Furnace, and other Combustion Applications Total NOx Measurements Up to 5 Total Gas Sensors Wireless Remote Printer External Water Trap with Filter Gas Velocity with Pitot Tube Rechargeable Battery Internal Memory (1000 Tests) Wireless Communications with Computer & Remote Printer REAL-TIME Software Package with BlueTooth Wireless & USB Up to Five Gas Sensors Including Both NO + NO2 for Total NOx LOW NOx Sensors Available with 0.1 ppm Resolution “Built with Quality...

 Open the catalogue to page 6

Low NOx and Total NOx The E5500 can be configured with low range NOx gas sensors with 0.1 ppm resolution and greater accuracy for low NOx concentration measurements. Total NOx, with direct actual measurements of both NO and NO2, is available with the E5500. Real-Time Software The standard “EGAS” software package includes the ability to save & graph data in realtime in the field with a laptop or in a laboratory with a PC. Communications between the E5500 and a computer are done via wireless Bluetooth communications or USB cable. A Bluetooth module for a computer comes standard with each E5500 gas...

 Open the catalogue to page 7

E5500 Specifications Gas Sensors The E5500 can have a maximum of five total gas sensors, that are electrochemical type gas sensors. The chart below details each sensor. Temperature Measurements Draft, Pressure, & Velocity Temperature measurements for the flue gas and air as well as the differential temperature are standard features. The differential temperature is used as part of the efficiency calculation. An internal pressure sensor allows the analyzer to measure pressure and stack draft. With two pressure inputs, a differential pressure can also be measured. Gas velocity can be measured using...

 Open the catalogue to page 8

E5500 E5500 Ordering Code Part # E5500 - Table A - Table B Table A - Electrochemical Gas Sensors N S 5 O2, CO, NO, & NO2 Sensors (with CO Dilution Auto-Range up to 20,000 ppm) O2, CO, NO, & SO2 Sensors (with CO Dilution Auto-Range up to 20,000 ppm) O2, CO, NO, NO2, & SO2 Sensors (with CO Dilution Auto-Range up to 20,000 ppm) Table B - Sampling Probes and Hoses Standard E5500 Configuration Includes the following: -External water trap assembly with mounting piece -Rechargeable battery pack -110-240VAC/50-60Hz battery charger -Stack gas & air temperature measurements -Draft & differential measurements...

 Open the catalogue to page 9

E8500 Portable Industrial Flue Gas & Emissions Analyzer Providing the latest in Combustion Gas & Emissions Analyzers for Boiler, Engine, Furnace, and other Combustion Applications Built-In Thermoelectric Chiller Automatic Condensate Drain Pump Wireless Remote Printer CO Dilution Auto-Range True NOx Measurements Up to 9 Total Gas Sensors NDIR Sensors Gas Velocity with Pitot Tube Rechargeable Battery Internal Memory Wireless Communications with Computer & Remote Printer Up to Nine Gas Sensors Including NDIR Bench for CO2, CxHy, High CO REAL-TIME Software Package with BlueTooth Wireless & USB LOW...

 Open the catalogue to page 10

Thermoelectric Chiller with Auto Condensate Drain The internal thermoelectric chiller efficiently and quickly removes the water vapor from the flue gas sample to prevent combustion gases from bubbling from the gas phase into the condensate. The built-in condensate drain pump automatically pumps the accumulated water out through the bottom of the unit for greater convenience. Real-Time Software The standard “EGAS” software package includes the ability to save & graph data in realtime in the field with a laptop or in a laboratory with a PC. Communications between the E8500 and a computer are done...