Transmitters for Moisture Content in Oil

E+E Transmitter Series EE36 are specially designed for the measurement of water content in oil. They are certified in accordance with the regulations of the "Germanischen Lloyd (GL)" and therefore can be utilized in the maritime field as well. The Series EE36 is ideal for online monitoring of mois-
ture in lubrication or insulation oil, which is very important for the long-term performance and adaptive maintenance of plant and machinery. For instance, moisture affects dramatically the insulation characteristics of electrical transformer oil and therefore continuous monitoring is extremely important. Humidity measurement in oil Similar to the humidity in the air, the water content in an oil can be described by the absolute value in ppm or by the relative value a >
w : - ppm (mass of water / mass of oil)
- a >

EE36 + Ball valve set

w (actual water content as fraction of the water content in the saturated oil) a >
w = 0 corresponds to water-free oil, while a >
w = 1 describes fully saturated oil. a >
w measurement with EE36 transmitter series is based on the outstanding long term stability and resistance to pollution of the E+E capacitive sensor elements series HC. Product Versions The physical quantities measured are water activity a Installation >
w and temperature T. With these quantities EE36 calculates the water content (ppm) in mineral transformer oils. Calculation of water content in non-mineral transformer oils and lubrication oils can be accomplished by downloading specific parameters of the oil. The measured and the calculated values are available on two free scaleable and configurable analogue outputs. In addition, an optional relay output can be used for alarms and process control. The sensing probe is designed for inline monitoring and can be placed directly in the oil, at pressures up to 20bar >
(300psi) . In addition to direct mounting of the sensing probe, a ball valve installation provides mounting and removal of the probe without interrupting the process. Easy Calibration and Adjustment of EE36 The user can easily readjust or calibrate the transmitter by using either a simple procedure with two push buttons on the printed circuit board or the configuration software. >

T

The configuration software is included in the scope of supply and allows an easy and fast configuration of the analogue outputs and of the alarm and control thresholds. Further features of the configuration software are adjustment and calibration of the outputs and service operations such as replacement of the sensing elements or of the entire sensing probe. >

EE

Measurement of a >
w and T at pressure up to 20bar >
(300psi) Calculation of water content in ppm for mineral transformer oil Two free scaleable and configurable analogue outputs Probe cable length up to 20m >
(66ft) Easy on site adjustment and calibration of a LED indication for operation and sensing probe status >
w and T outputs User configuration of the instrument with PC via RS232 interface Configuration software Display of a >
w , T and water content with MIN/MAX function optionalConnector for power supply and outputs optional optionalTwo free configurable relays outputs optional
Replaceable sensing probe >

I

A power supply, integrated in the back module of the housing, can be ordered optionally (100...240V AC, 50/60Hz; ordering code V01). The power supply V01 is available for both polycarbonate and metal housing and comes standard with two plugs for supply and outputs to allow an easy connection. >
v2.0

EE

55 >

E+E Product Catalogue 2009 / 2010
  1. P. 1

  2. P. 56

    HUMIMAP 20 measurement of relative humidity and temperaturecalculated values h, r, dv, Tw, Td, Tf, e expandable up to 32 channels (also later on)two freely...
  3. P. 57

    T D Measuring values Relative humidity Humidity sensor >1) HC1000-400 Working range >1) 0...100% RH Accuracy >*) (including hysteresis, non-linearity...
  4. P. 58

    O HUMIMAP20- Hardware Configuration Number of plug-in modules 1 piece 01 2 pieces 02 3 pieces 03 4 pieces 04 5 pieces 05 Cable length 2m >(7ft)...
  5. P. 59

    HUMLO 10 Humidity / TemperatureData Logger HUMLOG 10 series humidity/temperature data loggers permit the exact and professional recording of humidity...
  6. P. 60

    T A museums and exhibition spacesclean roomsgreen houseswarehouses data memory for 120,000 valueslarge format displayeasy installation and serviceuser...
  7. P. 61

  8. P. 62

    H D I E Housing: ball valve installation polycarbonate housing metal housing (pressure-tight up to 10bar/ 145psi ) 135 (5.3) > 66.5 (2.6Ԕ)...
  9. P. 63

    T D Measuring values Water activity Water activity sensor >1) HC1000-400 Measuring range >1) *) 0...1 a >w Accuracy (including hysteresis, non-linearity...
  10. P. 64

    YOUR PARTNER IN SENSOR TECHNOLOGY ELEKTRONIK9 Ges.m.b.H. EE36- Hardware Configuration Housing metal housing polycarbonate housing1'...
  11. P. 65

    EE1 Compact Transmitter / Switch for Moisture Content in Oil Humidity measurement in oil Similar to the humidity in the air, the water content in oil...
  12. P. 66

    D C D 40 (1.6) 24 (1Ԕ) 75 (3) analogue output 1 V+2 GND3 GND4 OUT15 OUT26 NC7 NC (1.9Ԕ) 6 7 1 10...30V DC 48 5 2 VmA 4 3 VmA (4) 100 relay...
  13. P. 67

  14. P. 68

  15. P. 69

  16. P. 70

  17. P. 80

  18. P. 90

  19. P. 100

Text version

All E E ELEKTRONIK catalogues and technical brochures

  1. Oilport 20

    2 Pages

    En
  2. EE381

    3 Pages

    En
  3. EE36

    4 Pages

    En
  4. HC103M2

    2 Pages

    En
  5. HC201

    2 Pages

    En
  6. HC109

    2 Pages

    En
  7. HCT01

    4 Pages

    En