EE0

Small Size Humidity / TemperatureTransmitter for OEM Applications

The analogue humidity output provides according to model type, a current signal with 4-20mA or a voltage signal with 0-1V. A passive temperature output signal is available for both versions. The voltage version can be ordered also with an active output.Wide temperature and supply voltage ranges, excellent long term stability and the optional sensor coating allow the use in many applications.

EE06 T AT D

stables green houses humidifiers and dehumidifiers monitoring of storage rooms very small dimensionsexcellent price/performance ratiovery good long term stabilityeasy installationoptional sensor coating Measuring values

EE06-x1
(voltage output)
EE061-x6
(current output)
Relative humidity
Sensor HC101 HC105 Working range
1) 0...100% RH 0...100% RH Analogue output 0...100% RH 0-1 V -0.2 mA
L
L <500Ohm Accuracy at 20°C
(68°F) , 12V DC ±3% RH (10...90% RH) ±3% RH (10...90% RH) ±5% RH (<10% RH and >90% RH) ±5% RH (<10% RH and >90% RH) Temperature dependence [% RH/°C] model F/FT: -0.00035 x RH x (T-20°C) model F/FP: typ. ±0.03 model FP: typ. (-0.003 x RH + 0.01) x (T-20°C)
Temperature active
Sensor Pt1000 (class A, DIN EN 60751) Analogue output -40...60°C
(-40...140°F) 0-1 V -0.2 mA
L
(68°F) ±0.3°C
(±0.5°F)
Temperature passive
Output resistive, 2 wire resistive, 4 wire Type of T-Sensor refer to ordering guide refer to ordering guide

General

Supply voltage 4.5V DC - 30V DC 9V DC - 28V DC Current consumption typ. 1.5 mA Electrical connection cable with 0.5m
(1.6ft) or 3m
(9.8ft) cable with 0.5m
(1.6ft) or 3m
(9.8ft) Housing polycarbonate / IP65 in vertical mounting polycarbonate (filter cap upside) IP65Sensor protection membrane filter, metal grid filter membrane filter, metal grid filterElectromagnetic compatibility EN61326-1 EN61326-1 EN61326-2-3 EN61326-2-3 Temperature ranges working temperature: -40...60°C
(-40...140°F) working temperature: -40...60°C
(-40...140°F) storage temperature: -40...65°C
(-40...149°F) storage temperature: -40...70°C
(-40...158°F) 1) Refer to the working range of the humidity sensor v2.4

EE0

43