Catalogue E+E Product Catalogue 2007/2008
www.epluse.at
print switch display
Page / 154
Make a request   
E E ELEKTRONIK - 157422, 40179, 2090, 3076
/ 154
See all the products E E ELEKTRONIK
Text version of the page

OO EE2 EE2

EE29-EE29-EE29-EE29-

Hardware Configuration

Housing metal housing MMMM polycarbonate housing PPPPType humidity + temperature FTFTFTFTModelABDEFilter stainless steel sintered filter 3333 PTFE Filter 5555 metal grid filter (up to 120°C /
248°F ) 6666 stainless steel grid filter (up to 180°C /
356°F ) 99Cable length 2m
(6.6ft) 0202
(incl. probe length) 5m
(16.4ft) 0505 10m
(32.8ft) 1010 20m
(65.6ft) 2020Probe length 65mm
(2.6”) 22 200mm
(7.9”) 555 400mm
(15.8”) 666Pressure tight 1/2” male thread HA03feedthrough 1/2” Pipe weld joint HA05 1/2” NPTthread HA07Display without displaywith display D05D05D05D05Alarm output
1) without relay with relay SWSWSWWPlug cable glands 1 plug for power supply and outputs C03C03C03C03 2 plugs for power supply/outputs and RS232 C07C07C07C07Sensing probe fixedinterchangeable P01P01Coating sensor noyes HC01HC01HC01HC01Calibration standardhigh-humidity calibration CA01CA01CA01Supply voltage 8...35V DC / 12...30V ACintegrated power supply 100...240VAC, 50/60Hz
2) V01V01V01V01

Software Configuration

Physical parameters Relative humidity RH [%] (A) Output 1 Select according to Ordering Guide (Aor B) of outputs TemperatureT[°C or °F] (B) Output 2 Select according to Ordering Guide (Aor B) Type of 0-5V (2)output signals Select according to Ordering Guide (2,3,5,6) 0-10V (3) 0-20mA (5) 4-20mA (6)Temperature unit °C°F E01E01E01E01Scaling of T-output -40...60 (T02) -20...80 (T24) 0...350 (T89) Output T Select according to Ordering Guide (Txx)Other T-scaling refer to page 134 in°C or °F 0...50 (T04) 0...180 (T26) 32...120 (T90) 0...100 (T05) -40...180 (T52) 32...140 (T91) 0...60 (T07) -40...100 (T79) 32...180 (T92) -40...120 (T12) -40...350 (T82) 32...250 (T94) 0...120 (T16) -40...140 (T83) 32...300 (T95) 0...80 (T21) -40...300 (T84) 32...132 (T96) -40...80 (T22) 0...250 (T88) 32...350 (T101)
1) Combination alarm output and plugs is not possible (with cable glands only) / combination alarm output and integrated power supply is not possible2) Integrated power supply includes 2 plugs for power supply and outputs / further plug options are not possible

A / RA / R P P

A A 28 28

- Filter caps (HA0101xx)- Bracket for installation onto mounting rails(HA010203)- Display + housing cover in metal(D05M)- Drip water protection(HA010503)- Display + housing cover in polycarbonate(D05P)- 1% Calibration(EE90/3H)- Replacement sensor(Pxx)- Calibration set(HA0104xx)- Humidity sensor(FE10)- Datalogging and analysis software (HA010602)- Interface cable (HA010301)(for EE31 only)- Mounting flange(HA010201)- RS485 Kit (HW + SW) for networking (HA010601)- Mounting flange 5mm (HA010208)(for EE31 only) (for EE31, model H only)

EE2

17

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-154
pdf-page pdf di En 2008-10-42-14