TT D D EE2 EE2

Measurement valuesRelative humidity

Humidity sensor
1) HC1000-400 Working range
1) 0...100% RHAccuracy
*) (including hysteresis, non-linearity and repeatability, traceable to intern. standards, administrated by NIST, PTB, BEV...)-15...40°C
(5...104°F) <90% RH± (1.3 + 0.3%*mv) % RH-15...40°C
(5...104°F) >90% RH± 2.3% RH-25...70°C
(-13...158°F) ± (1.4 + 1%*mv) % RH -40...180°C
(-40...356°F) ± (1.5 + 1.5%*mv) % RH Temperature dependence of electronicstyp. ± 0.01% RH /°C(0.0055% RH / °F) Response time with metal grid filter at 20°C / t
90 < 15s

Temperature

Temperature sensor manufacturer elementPt1000 (Tolerance class A, DIN EN 60751) Working range sensing head EE29-xAx-40...60°C
(-40...140°F) EE29-xBx-40...80°C
(-40...176°F) EE29-xDx-40...180°C
(-40...356°F) EE29-xEx-40...180°C
(-40...356°F) Accuracy (typ.)
∆ °C °C Temperature dependence of electronicstyp. ± 0.005°C/°C

Outputs

2) Two freely selectable and scaleable analogue outputs0 - 5V-1mA< IL< 1mA0...100% RH / xx...yy°C respectively0 - 10V -1mA< IL< 1mA4 - 20mAR
L < 500 Ohm 0 - 20mAR
L < 500 Ohm

General

Supply voltageSELV 8...35V DC
SELV = Safety Extra Low Voltage SELV 12...30V AC (optional 100...240V AC, 50/60Hz)Current consumption- 2x voltage outputfor 24V DC/AC:typ. 40mA - 2x current outputtyp. 80mA Pressure range for pressure tight sensor0.01...15bar (0.15...218psi) System requirements for software WINDOWS 98 or later; serial interface Housing / protection classPC or Al Si 9 Cu 3 / IP65;
Nema 4 Cable gland M16 x 1.5 cable Ø 4.5 - 10 mm
(0.18 - 0.39”) Electrical connection screw terminals up to max. 1.5mm²
(AWG 16) Sensor protectionstainless steel sintered filter, PTFE filter or metal grid filterWorking and storage temperature range of electronics-40...60°C
(-40...140°F) -20...50°C
(-4...122°F) - housing with displayElectromagnetic compatibility according toEN61000-6-2EN61000-6-3ICES-003 ClassB EN61326-1+A1+A2 FCC Part15 ClassB
1) Refer to the working range of the humidity sensor. 2) Can easily be changed by software.*) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).

EE2

14

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-154
pdf-page pdf di En 2008-10-42-13